Laserfiche WebLink
aFpnnrxrsA, Safety and Buildings <br /> X5.2 Tom, 10541N RANCH ROAD <br /> HAYWARD WI 54843 <br /> Contact Through Relay <br /> s P www.dspsmi.govlsb/ <br /> TyQp , v.+N.v.wisconsin.gov <br /> �O$$swN A� � Scott Walker,Governor <br /> Dave Ross,Secretary <br /> October 01,2012 <br /> CUST ID No. 225851 AM. POWIS Inspector <br /> RICHARD HOPKINS ZONING OFFICE <br /> HOPKINS SAND&GRAVEL BURNETT COUNTY SPIA <br /> 27760 HWY 35 7410 CTH K#102 <br /> WEBSTER WI 54893 SIREN WI 54872 <br /> CONDITIONAL APPROVAL <br /> PLAN APPROVAL EXPIRES: 10/01/2014 Identification Numbers <br /> Transaction ID No.2154466 <br /> SITE: Site ID No. 784395 <br /> Kevin Berry Please refer to both identification numbers, <br /> 22989 Co Rd M above,in all correspondence with theagency. <br /> Town of Wood River <br /> Burnett County <br /> ,S26,T3 8N,R1 8W <br /> FOR: <br /> Description:Mound, 1-2 bedroom residence& 1-1 bedroom cabin <br /> Object Type:POWTS Component Manual Regulated Object ID No.: 1393621 <br /> Maintenance required; Replacement system; 450 GPD Flow rate; 28 in Soil minimum depth to limiting factor from <br /> original grade; System(s): Ezflow Mound Component Manual,(K 8/07),Pressure Distribution Component Manual- <br /> Version 2.0, SBD-10706-P(N.01/01), SSWMP Pub. 9.6; Effluent Filter <br /> The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes <br /> and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. This system is to be constructed P.O.W.f., <br /> and located in accordance with the enclosed approved plans and with any component manual(s)referenced above. (;On dtif1011 <br /> The owner,as defined in chapter 101.01(10),Wisconsin Statutes,is responsible for compliance with all code t <br /> requirements. <br /> No person may engage in or work at plumbing in the state unless licensed to do so by the Department per s.145.06,A <br /> stats. DN' F�gF�'iY AP <br /> The following conditions shall be met during construction or installation and prior to occupancy or use: �"— <br /> Key Item(s) A <br /> E co <br /> • In the event this soil absorption system or any of its component parts malfunctions so as to create a health <br /> hazard,the property owner must follow the contingency plan as described in the approved plans. In addition,the <br /> owner must insure that the operation,maintenance and monitoring duties as described in section VIII of the <br /> mound component manual are complied with.A copy of this information must be given to the owner upon <br /> completion of the project. <br /> • Following the removal of the old sand fill,and prior to the construction of the system,check the moisture <br /> content of the soil to a depth of 8 inches.If the site is too wet to prepare,do not proceed until it dries. It is the <br /> recommendation of the department that the tanks be pumped for a couple of weeks prior to the mound removal <br /> procedure.This will help insure that the soil will have a chance to dry and retain some structure during the <br /> stripping process.Remove as much material from the upslope side as feasible.Tracked equipment on the site is <br /> required. <br /> • The bottom of the distribution cell shall be level per the Mound Component Manual. The"D"dimension shall <br /> be a minimum of 8". The maximum finished slope of the mound surface shall not have a slope ratio steeper <br /> than 3:1 per the Mound Component Manual <br />