XExisting and proposed driveway(s);must show dimensions and width *Driveways must have a cleared width of 20 ft and a <br /> cleared height of 13 ft <br /> North arrow <br /> Vegetation proposed to be removed or disturbed <br /> Existing and proposed utilities and utility easements <br /> Location and extent of proposed filling/grading <br /> Location and type of erosion-control measures <br /> Fall radius and fall zone <br /> Distance to all nearby structures,within a distance equal to the height of the tower,as measured from the center of the tower <br /> +\ Any other construction related to your project <br /> • Construction plans shall be submitted with this application for all items subject to Uniform Dwelling Code(UDC) <br /> inspection. Construction plans shall show interior layout, exterior profiles, and exterior heights. <br /> • Construction plans shall be submitted with this application for all non-dwelling(Commercial/Industrial)related <br /> construction. Construction plans shall show interior layout, exterior profiles,and exterior heights. <br /> • Proposed building/structure locations must be staked prior to submitting this application to the Zoning Office. County <br /> staff will do an onsite visit to verify site conditions. If all proposed structures(including fences,out buildings,retaining <br /> walls, etc)are not staked upon County staff visit, the permit will NOT be issued and it will be returned to the applicant. <br /> • If all existing structures on the parcel are not shown and dimensioned on the plot plan drawing, the permit will NOT be <br /> issued and it will be returned to the applicant. <br /> If this application is to substantially modify an existing support structure, a construction plan is required which <br /> describes the proposed modifications to the support structure and the equipment and network components, including; <br /> antennas,transmitters, receivers, base stations, power supplies,cabling, and related equipment associated with the <br /> proposed modifications. <br /> If this application is to construct a new support structure, a construction plan is required which describes the proposed <br /> support structure and the equipment and network components, including; antennas,transmitters,receivers, base <br /> stations,power supplies, cabling, and related equipment to be placed on or around the proposed structure. <br /> If this application is to construct a new support structure,an explanation is required as to why the applicant chose the <br /> proposed location and why the applicant did not choose collocation,including a sworn statement from an individual <br /> who has responsibility over the placement of the support structure attesting that collocation within the applicant's <br /> search ring would not result in the same service functionality, coverage, and capacity; is technically infeasible; or is <br /> economically burdensome to the service provider. <br /> A structural certification is required showing that the support structure, or existing structure is designed to collapse <br /> within a smaller area than the fall zone, if applicable. <br /> Page 3 of 5 <br /> Burnett County, WI Tower Application —Rev 1/2017 <br />