Laserfiche WebLink
HOLDING TANK MANAGEMENT PLAN <br /> This Private Onsite Wastewater Treatment System(POINTS)has been designed,and is to be installed and <br /> maintained according tomm 8/�, WIS.Admin.Code,the Holding Tank Component Manual (SBD-10571-P <br /> 6/11/1999), and the .V911 County Sanitary Ordinance. <br /> 1. This POWTS Is designed to accommodate an es immed domestic wastewater ftow of 300 gpd. <br /> 2. The owner of this POWTS is responsible for system operation and maintenance, including all provisions in <br /> the attached Holding Tank Servicing Contract and Maintenance Agreements. <br /> 3. Each time the wastewater in the tank reaches 90% of the tank(s)capacity or a level of 12"below the inlet <br /> (al which time the alarm will activate),the pumper listed to the Current Servicing Contract must be called t0 <br /> empty the tank's contents and dispose of them in accordance with NR 113, Wis.Adm. Code. <br /> 4. At each service event, the service provider should visually inspect the Condition of the tank, ffsefs and <br /> manhole Cover(s) and verify that the alarm system functions and manhole locking devices are present. <br /> Discrepancies are reported to the owner in a timely manner for corrective action. All Corrective actions <br /> shall Comply with the County sanitary Ordinance and Comm 83 and 84 Wis.Adm. Code. <br /> 5. All service events or inspections of this POWTS shall be reported to the County within 10 business days. <br /> 6. The owner may not remove any Of the wastes from the holding tank(s),Or cause such wastes to be <br /> removed by any person not authorized to do so under Ch.281, Wis.Statutes. The dlsCharge Of wastes <br /> tank to the ground surface, including intentional discharges and discharges caused by neglect, constitutes <br /> a failing POWTS and may result in issuance of Correction orders or a Citation by the county or slate. <br /> 7. No one should enter a holding tank for any reason without being in full Compliance with OSHA standards <br /> for entering a confined space. The atmosphere within these tanks may Contain lethal gases, and rescue <br /> of a person from the interior of the tank may be difficult or impossible. <br /> 8. In the event that this POWTS fails and cannot be repaired,a code Compliant replacement holding tank <br /> may be installed in the same location(a new sanitary permit is required for such a replacement). Con- <br /> nection t0 municipal services would also be Considered at this time if they are deemed available to the <br /> property. <br /> 9. If this POWTS is replaced, or its use discontinued, components no longer in use it shall be abandoned in <br /> accordance with Comm 83.33 Wis_Adm.Code. <br /> 10. If there is a problem with, or quash about this/4raYation, the following persons should be contacted: <br /> a. installer.............._....__.... 05%_10/f9�f0' _ Phone:_h0a-zbb <br /> b. Service Provider............... ip»�{ 5 iG Phone:vat_12 � <br /> C. Co. Zoning or Health Dept. vrr�pff (�._'1C,W.ir` Phone:-3 y7. <br /> 11. <br /> Project <br /> Transaction Number: Page 4 of 4 <br />