Laserfiche WebLink
Safety and Buildings <br /> 10541 N RANCH ROAD <br /> HAYWARD WI 54843 <br /> TDD#:(608)264-8777 <br /> 1*h4consin www.commerc .\&is onsin.gov <br /> www.wisconsin.gov <br /> Department of Commerce <br /> Scott McCallum,Governor <br /> Philip Edw.Albert,Secretary <br /> July 30,2002 <br /> CUST ID No.225229 ATTN:POWTS Inspector <br /> NELS D KOERPER ZONING OFFICE <br /> CENTRAL PLUMBING AND HEATING BURNETT COUNTY SPIA <br /> 7845 CTY RD D 7410 CTH K#102 <br /> WEBSTER WI 54893 SIREN WI 54872 <br /> CONDITIONAL APPROVAL <br /> PLAN APPROVAL EXPIRES:07/30/2004 TransIdentification Numbers <br /> action ID No.772492 <br /> SITE: Site ID No.648293 <br /> David&Audrey Johnson Please refer to both identification numbers, <br /> N Mud Hen Lake Rd above,in all correspondence with the-agency. <br /> Town of Daniels <br /> Burnett County <br /> NE1/4,NEI/4,S17,T38N,R17W <br /> Lot: 1, <br /> FOR: <br /> Description:Holding Tank 450 Gpd. <br /> Object Type:POWT System Regulated Object ID No.: 863004 <br /> The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes <br /> and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner,as defined in <br /> chapter 101.01(10),Wisconsin Statutes,is responsible for compliance with all code requirements. <br /> The following conditions shall be met during construction or installation and prior to occupancy or use: <br /> Correspondence Notes: <br /> 1. Comm 83.54(2),A water meter shall be installed by a properly licensed plumber,on the water system, <br /> that adequately measures the amount of water used by the structure,excluding hose bibs and wall <br /> hydrants,which do not discharge into the sanitary system. <br /> • Comm 83.43(8)(8),Anchor tank as necessary to negate buoyant forces.If a holding tank component is to <br /> be installed in saturated soils,as determined by a certified soil tester,it shall be anchored. <br /> • Comm 84.10,All materials used in this installation shall conform to the provisions of this chapter. <br /> • Comm 83.61(5)Holding Tank Component Manual SBD-10571-P(R.6/99)Table 1, Manhole cover or <br /> service port to be no more than 25' from service road or drive. <br /> • Comm 83.61(5) This system is to be constructed and located in accordance with the enclosed approved Q , <br /> plans and with the Holding Tank Component Manual,SBD-10571-P(R.6/99). COO <br /> A copy of the approved plans,specifications and this letter shall be on-site during construction and open to <br /> inspection by authorized representatives of the Department,which may include local inspectors. All permits <br /> required by the state or the local municipality shall be obtained prior to commencement of <br /> construction/installation/operation. <br />