Laserfiche WebLink
III Safety and Buildings <br /> 10541 N RANCH ROAD <br /> commerce.wi.gov HAYWARD WI 54843 <br /> TDD#:(608)264.8777 <br /> tlscnsin wvne cwwwommer govsb, <br /> .wisoonisconsin.gov <br /> epartrnent of Commerce <br /> Jim Doyle,Governor <br /> Mary P.Burke,Secretary <br /> May 14,2007 <br /> CUST ID No. 851954 AT77V:POWTS Inspector <br /> ZONING OFFICE <br /> ROSS JEREMY TOLLANDER BURNETT COUNTY SPLA <br /> 27220 JAMISON RD 7410 CTH K#102 <br /> WEBSTER WI 54893 SIREN WI 54872 <br /> CONDITIONAL APPROVAL Identifica on Numbers <br /> PLAN APPROVAL EXPIRES: 05/14/2009 Transaction ID No. 387488 <br /> Site ID No. 724494 <br /> SITE: <br /> Roland Salzman Please refer to both dentification numbers, <br /> Viola Lake Rd above,in all corres o idence with theagency. <br /> Town of La Follette <br /> Burnett County P.0` <br /> ,S6,T38N,R15E �r,• 1 <br /> FOR: WW n1 <br /> Description:Mound,3 bedroom residence AQ <br /> Object Type:POWTS Component Manual Regulated Object rD No.: 1127498 •_,vtM <br /> Maintenance required; 450 GPD Flow rate; 19 in Soil minimum depth to limiting factor in original grade; �! <br /> System(s): Mound Component Manual-Version 2.0, SBD-10691-P(N.01101) <br /> The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes SEEC,( <br /> and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. This systei n is to be <br /> constructed and located in accordance with the enclosed approved plans and with the componer t manual(s) <br /> referenced above.The owner,as defined in chapter 101.01(10),Wisconsin Statutes,is responsible for compliance <br /> with all code requirements. <br /> No person may engage in or work at plumbing in the state unless licensed to do so by the Dep ent per s.145.06, <br /> stats. <br /> The following conditions shall be met during construction or installation and prior to occupanc r or use: <br /> Key Item(s) <br /> • In the event this soil absorption system or any of its component parts malfunctions so as to create a health <br /> hazard,the property owner must follow the contingency plan as described in the approved plans.In addition, <br /> the owner must insure that the operation,maintenance and monitoring duties as described in section VIII of the <br /> mound component manual are complied with.A copy of this information must be given to the owner upon <br /> completion of the project. <br /> • The bottom of the distribution cell shall be level per the Mound Component Manual. The `D"dimension shall <br /> be a minimum of 17". The maximum finished slope of the mound surface shall be equal o or less than 3:1 per <br /> the Mound Component Manual. <br /> • The designer proposes to install a state approved effluent filter to achieve the requirement f wastewater <br /> particle size. Pursuant to outlet filter product approval stipulations,maintenance information must be given to <br /> the owner of the POWTS explaining that periodic cleaning of the effluent filter is required. The access opening <br /> used to service the filter shall terminate at or above finished grade with a watertight cover. <br /> Reminder <br /> • The orientation of the mound system must be such that the longest dimension is oriented along the surface <br /> contour per COMM 83.44(6)(a)2. <br />