Laserfiche WebLink
Page 4a+b of 4 1 <br /> POWTS OWNER'S MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> OWNER John Hansen Septic Tank Capacity 750 Gal. <br /> PERMIT# Septic Tank Manufacturer Wieser Concrete <br /> Effluent Filter Manufacturer Pol lok <br /> DESIGN PARAMETERS Effluent Filter Model PL-525 <br /> Number of Bedrooms 2 Filter Canister Na <br /> Number of Commercial Units --- Pum Tank Manufacturer Na <br /> Estimated Daily Flow 200 gal/day Pump Manufacturer Na <br /> Design Flow Peak Est.x 1.5 300gal/day Pwnp Model Na <br /> Soil Application Rate .7 /fl2 Pretreatment Uni i n/a <br /> Influent/Effluent Quality Monthly Average i Sand/Gravel Filter 1 Peat Filter <br /> Fats,Oils&Grease(FOG) <30 mg/L i Mechanical Aeration i Wetland <br /> Biochemical Oxygen Demand($ODs) 5 220 mg/L i Disinfection i Others: <br /> Total Suspended Solids TSS <150 m <br /> Pretreated Effluent Quality I n/a Monthly Average Dispersal Cell(s) 1-3ft.x"ft. <br /> Biochemical Oxygen Demand (BODS) <30 mg/L X in-ground gravityi in-ground(pressurized) <br /> Total Suspended Solids(TSS) <_30 mg/L i At-grade i Mound <br /> Fecal Coliform (geometric mean) !S IW cfir/100ml i Drip-line i Other: <br /> Maximum Effluent Particle Size %inch diameter j EZ Flow.EISA Rating of 50 sq.ft. <br /> MAINTENANCE SCHEDULE <br /> SERVICE EVENT SERVICE FREQUENCY <br /> Inspect condition of tank(s) At least once every I months 3 year(s) (Maximum 3 ears <br /> Pump out contents of tanks When combined sludge and scam equals one-third /3 of tank volume <br /> Inspect dispersal cells At least once every I months 3 years Maximum 3 ears <br /> Clean effluent filter At least once every I months 1 ears or as needed <br /> Inspect pump,pumpcontrols and alarm At least once every months 1 years n/a <br /> Maintenance Instructions <br /> Inspections of tanks and dispersal cells shall be made by a individual carrying one of the following licenses or certifications: Master <br /> Plumber;Mater Plumber Restricted Sewer;POWTS Maintainer; Septage Servicing Operator. Tank inspection must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined <br /> sludge and scum and to check for any back up or ponding of effluent on the ground surface. The dispersal cell(s)shall be visually <br /> inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface. The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local <br /> authority. <br /> When the combined accumulation of sludge and scum in any tank equals one-third(1/3)or more of the tank voluune,the entire <br /> contents of the tank shall be removed by a Septage Servicing Operator and disposed of in accordance with ch.NR 113, Wisconsin <br /> Administrative Code. <br /> The servicing of effluent filters,mechanical or pressurized POWTS components,pretreatment components,and any other <br /> maintenance or monitoring at intervals of 12 months or less shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 10 days of completion of any service event. <br /> START UP AND OPERATION <br /> For new construction,prior to use of the POWTS check treatment tank(s)for the presence of painting products or other chemicals that <br /> may impede the treatment process and/or damage the dispersal cell(s). If high concentrations are detected have the contents of <br /> the tank(s)removed by a septage servicing operator prior to use. <br /> System start up shall not occur when soil conditions are frozen at the infiltrative surface. <br />