kQL INGQ TANK IUTANAGEIVIENT PLAN <br /> This Private onsite Wastewater Treatment Systeirl ;POWTq has been designed, and is to be installed <br /> and maintained according to Comm a3, Wis. Adndn, Code, the Holding Tank Component Manuel for <br /> Private Onslte Wastewater Treatment Systems (ET )-10571-P; June 11, 1999), and the—4;c Irl <br /> County Private Sewage System Ordinance, <br /> 1. This POWTS has been designed to accommodate a maximum daily flow of <br /> 2�3ar2 gallons of domestic wasle water per day. <br /> 2. The owner of this POWTS is leapt., tible for system operation and maintenance, <br /> including all provisions in the attachod Holding Tank Servicing Contract and <br /> Maintenance Agreements. <br /> 3, Each time the wastewater in the tank reaches 90% of the tank(s) capacity or a <br /> level of 12" below the inlet (at which time the alarm will activate), the pumper <br /> listed in the current Servicing COMTE2t must be called to empty the tank contents <br /> and dispose of them in accordance with NR 113, Wis. Admin. Code. <br /> At each pumping the pumper should visually inspect the condition of the tank, <br /> risers and manhole cover(s) and verify that any required locks are present. <br /> 4. The owner may not remove any of the wastes from the holding tanks, or cause <br /> such wastes to be removed by any person not authorized to do so under Ch. <br /> 281, Wis. Statutes. The discharge cf wastes from this holding tank to the ground <br /> surface, Including intentional discharges end discharges caused by neglect, <br /> constitutes a failing private sewage system and may result in Issuance of <br /> correction orders by the county. <br /> 5. Anytime a defect is identified or malfunction occurs, it shall be reported to the <br /> person(s) identified in the User's Manual for this POWTS. Repair or correction <br /> of such fail rs qr malfunction shall comply with Comm 83, Wis. Admin. Code, <br /> and the ,_,2 �� County Private Sewage System Ordinance. <br /> 6. No one should enter a holding tank for any reason without being in full <br /> compliance with OSHA standards for entering a confined space, The <br /> atmosphere within these tanks may contain lethal gases, and rescue of a person <br /> from the interior of the tank may be difficult or impossible. <br /> 7. In the event that this POWTS fails and cannot be repaired, a code compliant <br /> replacement holding tank may be installed in the same location (a new sanitary <br /> permit is required for such a replacement). <br /> 8. If this Powrs is replaced, or its use discontinued, it shall be abandoned in <br /> accordance with Comm 83.33, Wis, Admin, Code. Ea <br /> �D` p q 7006 <br /> ��.� &gD1lD1NGS <br />