Management Plans -Holding Tanks <br /> The Private Onsite Wastewater Treatment System(POWTS)has been designed, and is to be installed and maintained <br /> According Comm SPS 383, Wis.Admin. Code,Holding Tank Component Manual for Private Onsite Wastewater Systems. <br /> 1. This POWTS has been designed to accommodate a maximum daily flow of 45�o gallons of domestic wastewater per day. <br /> 2. The owner of this POWTS is responsible for system operation and maintenance, locking device, alarm and access. <br /> 3. The owner or owner's agent is required to submit reports as required by s.Comm SPS 383.55 (1),Wis.Admin. Code <br /> to the County or other appropriate jurisdiction and/or the department. <br /> 4. Design approval and site inspections before,during, and after the construction are accomplished by the county or other <br /> appropriate jurisdiction in accordance with ch. Comm SPS 383 of the Wis.Admin. Code. <br /> 5. Meter installation. A water meter is installed on the water supply discharging to the holding tank. All exterior hydrants <br /> are excluded from the metered flow. The meter is installed downstsream of all point-of-entry water treatment devices. <br /> A control valve is installed on each side of the meter. <br /> 6. Alarm installation. The alarm float is set to turn on the alarm when liquid volume is at 12"below tank inlet invert or <br /> at 90%of liquid capacity of the tank below the tank inlet invert. Alarm wiring is installed in accordance with <br /> NEC 300 and ILHR 16.23, Wis Admin.Code. <br /> 7. Maintenance cycle. The holding tank must be serviced by licensed pumpers. An alarm system is installed to activate <br /> when the tank is<=90%full. Water is conservation should be practiced at this point. <br /> 8. Performance monitoring.At the time of servicing,the service provider files a report with the department or designated agent <br /> 9 Anytime a failure or malfunction occurs, it shall be reported to the person(s)identified in the user's manual for this POWTS. <br /> 10. No one should enter a holding tank for any reason without being full compliance with OSHA standards for entering a <br /> confined space. The atmosphere within these tanks may contain lethal gases,and rescue of a person from the interior of the <br /> tank may be difficult or impossible. <br /> 11. In the event that this POWTS or a component of the POWTS fails and cannot be repaired,it must be replaced. <br /> 12. If this POWTS is replaced or its use discontinued, it shall be abandoned in accordance with Comm SPS 383.33 Wis Admin <br /> code. <br /> Contingency Plan—Holding Tanks <br /> To ensure public health,safety and minimize environmental impact,a contingency plan will be followed if necessary. <br /> If a holding tank failure were to occur,water conservation should be utilized and the following people called: <br /> Installer:Hopkins Sand&Gravel,27760 Hwy 35, Webster WI 54893 (715)866-4157 <br /> Pumper:A-1 Septic(715)656-7007,Chapman's Septic(715)656-7113, Steve's Septic(715)866-4195 <br /> Tank Manufacturer: Skaw Pre-cast 1-800-924-8625,Wieser Concrete 1-800-336-3416 <br /> Burnett County Zoning: (715)349-2138 <br /> Douglas County Zoning: (715)395-1380 <br /> Washburn County Zoning:(715)468-4690 <br /> Polk County Zoning: (715)485-9279 <br />