Laserfiche WebLink
HOLDING TANK SPECIFICATIONS <br /> 1 Number of bedrooms <br /> 300.0 Non-residential estimated flow(gpd) <br /> 2000.0 Minimum holding tank volume required (gal) <br /> 2000.0 Proposed holding tank capacity(gal) <br /> Wieser Tank Manufacturer <br /> WLP2000-MR Tank model number <br /> JElectro Alarm manufacturer <br /> Tank Alert ( Alarm model number <br /> Tank Dimensions and Data Tank Anchor Calculations <br /> X for round tank 22230 Ibs Weight of tank and cover <br /> 36.0 Liquid depth below inlet invert(in) Safety factor <br /> 8.0 Maximum depth of soil cover(ft) -22230 Ibs Weight of anchor required <br /> 55.0 Height(in) Outside -24.4 in Soil cover req. for anchor or <br /> 164.0 ILength (in) Dimensions -5.5 yd° Concrete counterweight <br /> 96.0 Width (in) I Only <br /> HOLDING TANK CROSS SECTION <br /> manhole cover with <br /> locking device and finished vent cap <br /> junction warning label grade <br /> box � <br /> 4"min. 1 „ 12"min. <br /> F—23 in. <br /> Manhole and vent locations <br /> conduit —� vent pipe <br /> 18"Imin. <br /> tether weight <br /> _ W <br /> building sewer <br /> service 12.0 in. inlet <br /> blind plug alarm on Note: All tank joints, and <br /> to seal joints between tank <br /> outlet openings and piping are <br /> Electrical as per 24.0 in. sealed watertight. All <br /> NEC 300 pipe and vent materials <br /> and SPS 316 comply with SPS 384. <br /> 3 in.bedding under tank. Tank is anchored as necessary to negate buoyancy. <br /> Project: Nelsen Holding Tank <br /> Transaction Number: Page 2 of 4 <br />