Chamber SAS <br /> SYSTEM ELEVATION AND SIZING CALCULATIONS <br /> Below Grade Chamber Soil Absorption Systems <br /> Marlene Kufalk lOwners Name 7/16/2002 Review Date <br /> DY or N Highly Pretreated Effluent <br /> 3 ft Suitable Soil x <br /> 16.5 in Chamber Height <br /> g ft Maximum Bury Depth 3 Check bury depth as per man_ufa <br /> Infiltrator High Capacity Sidewinder V <br /> ±70 <br /> gpd Estimated Daily Peak Flow gpd/ftz In-situ Wastewater Infiltration Rate ftZ Chamber Area <br /> gpd/ft2 Permitted Chamber Infiltration Rate 3 ft2 per Chamber <br /> 22 No. of Chambers <br /> 95.00 ft Proposed SAS Elevation <br /> Soil Surface Acceptable Finished Grade EL 4(ft) <br /> Boring Grade Limitation SAS Elevation (ft) System Minimum Maximum <br /> Number Elevation(ft) Depth(in) Lowest Highest Elevation? 97.38 104.38 <br /> 1 99.00 110 92.83 97.63 Yes <br /> 2 99.00 110 92.83 97.63 Yes <br /> 3 98.00 96 93.00 96.63 Yes <br /> 1. Depth of suitable soil required below the infiltrative surface for treatment. <br /> 2. Total height of chamber in inches. <br /> 3. Maximum bury depth as per manufacturer's recommendations. <br /> 4. Based on chosen system elevation,and chamber height. Top of chamber is <br /> equivalent to top of aggregate. The addition of fill for cover or the reduction of <br /> finished grade may be required to meet minimum or maximum code standards. <br /> Version 2.0 R.03/01 <br />