2005/02/07 - SANITARY - SAN - Other
Burnett-County
>
Property Files
>
TOWN OF WOOD RIVER
>
28944
>
2005/02/07 - SANITARY - SAN - Other
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2020 11:37:11 AM
Creation date
9/30/2017 4:26:42 PM
Metadata
Fields
Template:
Property Files v2
Document Date
2/7/2005
Document Type 1
SANITARY
Document Type 2
SAN
Document Type 3
Other
Tax ID
28944
Pin Number
07-042-2-38-18-24-3 03-000-012000
Legacy Pin
042252403400
Municipality
TOWN OF WOOD RIVER
Owner Name
DANIEL K MIDDLESTEDT
Property Address
10994 CROSSTOWN RD
City
GRANTSBURG
State
WI
Zip
54840
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
POWTS OWNER'S MANUAL 81 MANAGEMENT PLAN Page Lofd <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner ,41qr Septic Tank Capacity gal ❑ NA <br /> Permit# Septic Tank Manufacturer ❑ NA <br /> DESIGN PARAMETERS Effluent Filter Manufacturer A13 L-, ❑ NA <br /> Number of Bedrooms ❑ NA. Effluent Filter Model ❑ NA <br /> Number of Commercial Units Pump Tank Capacity gal ❑ NA <br /> Estimated flow (average) �� gal/day Pump Tank Manufacturer ❑ NA <br /> fc);�y=f�'fL <br /> Design flow (peak), (Estimated x 1.5) gal/day Pump Manufacturer zi���L�� ❑ NA <br /> Soil Application Rate /,0 gal/day/ft' Pump Model 5 ❑ NA <br /> Influent/Effluent Quality Monthly average* Pretreatment Unit PrNA <br /> Fats, Oil at Grease (FOG) 530 mg/L ❑ Sand/Gravel Filter ❑ Peat Filter <br /> Biochemical Oxygen Demand (BODS) 5220 mg/L ❑ Mechanical Aeration ❑ Wetland <br /> Total Suspended Solids (TSS) 5150 mg/l. ❑ Disinfection ❑ Other: <br /> Pretreated Effluent Quality A Monthly average** Manufacturer <br /> Dispersal Cell(s) <br /> Biochemical Oxygen Demand (BODS) 530 mg/L ❑ In-ground (gravity) ❑ In-ground (pressurized) <br /> Total Suspended Solids (TSS) 530 rng/L ❑ At-grade X Mound <br /> Fecal Coliform (geometric mean) 510' cru/100mI 1 ❑ Drip-line ❑ Other: <br /> Maximum Effluent Particle Size % inch diameter <br /> * Values typical for dontesdc (non-commercial)wastewater and septic <br /> tank effluent. <br /> ** Values typical for pretreated wastewater. <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Inspect condition of tank(s) At least once every <br /> C1 months (Maximum 3 yrs.) <br /> s <br /> Pump out contents of tank(s) When combined,sludge and scum equals one-third (Ys) of tank volume <br /> Inspect dispersal cell(s) At least once every ❑ months 0(years) (Maximum 3 yrs.) <br /> Clean effluent.filter At least once every ❑ months Pr year(s) �-,,f 15 ///Em'C'o <br /> Inspect pump, pump controls ez:alarm At least once every j ❑ months X year(s) ❑ NA <br /> Flush laterals and pressure test At least once every ❑ months ❑ year(s) ❑ NA .s' /tfG-rOCO <br /> other: At least once every ❑ months ❑ year(s) ❑ NA <br /> Other: At least once every ❑ months ❑ year(s) ❑ NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications: Master <br /> Plumber, Master Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer; Septage Servicing Operator. Tank inspections <br /> must Include a visual Inspection of the tank(s) to identify any missing or broken hardware, Identify any cracks or leaks, measure the <br /> volume of combined sludge and scum and to check for any back up or ponding of effluent on the ground surface. The dispersal <br /> cell(s) shall be visually inspected to check the effluent levels In the observation pipes and to check for any ponding of effluent on <br /> the ground surface. The ponding of effluent on the ground surface may Indicate a failing condition and requires the immediate <br /> notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any tank equals one-third (Ys) or more of the tank volume, the entire <br /> contents of the tank shall be removed by a Septage Servicing Operator and disposed of in accordance with ch. NR 113, Wisconsin <br /> Administrative Code. <br /> The servicing of effluent filters, mechanical or pressurized POWTS components, pretreatensent components, and any other <br /> maintenance or monitoring at intervals of 12 months or less shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 10 days of completion of any service event. <br /> START UP AND OPERATION <br /> For new construction, prior to use of the POWTS check treatment tanks) for the presence of painting products or other chemicals <br /> that may Impede the treatment process and/or damage the dispersal cell(s). If high concentrations are detected have the contents <br /> ,f Lo t.nWc) romnupd by -3 conraoo condrina nnarafnr nrinr fn fico <br />