Laserfiche WebLink
PAGE ,11, OF 4 <br /> �n-ground Gravity Management Plan <br /> lfbpoff rANT., <br /> The mitmer of this in-ground gravity system shall be responsible for its perpetual operation and maintenance pursuant L w-o <br /> requirements of SPS 382-384,Wisc.Admin. Code. Pursuant to SPS 383.52(2),Wisc.Admin.Code,this system shall <br /> be considered a human health hazard if not maintained in accordance with this approved management plan. <br /> Furthermore,all inspection and maintenance activities shall be performed by a registered POWrS Maintainer in <br /> accordance with SPS 383.52(3),Wisc.Admin. Code. <br /> Maximum Dispersal Area Operating Limits: <br /> FEaw 90, B005 5 220 mgL"; TSS:5 150 rngUl; FOG 5 30 mgUl <br /> inspection Checkfls,i MPECT EVERY 3 YEARS <br /> • 'type of use <br /> • age of system <br /> • nuisance factors(i.e. odors, user complaints, etc.) <br /> • mechanical malfunction(i.e., pumps,valves,switches,floats, etc.) <br /> • material fatigue(i.e., leaks, breaks, corrosion, etc.) <br /> • solids volume in anaerobic treatment tank(s)and any distribution appurtenance(s)(i.e.,distribution drop boxes) <br /> • neglect or improper use(La., exceeding design capacities, prohibited activities, etc.) <br /> • extent of ponding in distribution cell prior to dosing <br /> • dosing irregularities-if applicable(La., pump re-cycling,float switch settings, etc.) <br /> • electrical components-if applicable(i.e.,wiring,connections,switches, controls,timers, alarms, etc.) <br /> • distribution lateral or lateral orifice plugging (measure lateral distal pressure-compare to design specifica-don') <br /> • surface discharge of effluent or sewage back-up into structure served <br /> 0,kfiaintenance Checklist HANTAIN EVERY 3 YEARS (or when necessary) <br /> • Septic and dose tank sj shall be pumped by a certified septage servicing operator licensed under s. 281.4e ANi5. <br /> Stats.when the volume of solids in the tank(s)exceeds one-third(113)the liquid volume of the tan ft(s)or <br /> as required by local ordinance. Disposal of contents shall be pursuant to NR 113,Wisc.Admin.Code. <br /> • Effluent fifterls)shall be inspected every 3 years and shall be cleaned when necessary to remove any <br /> accumulated solids according to manufacturer's specifications. A servicing period will always be greater than 12 <br /> months. <br /> System, maintenance reports shall be submitted to the proper local government unit in accordance with <br /> SPS 383.55 Wisc.Admin. Code. Report any component failure or malfunction to: <br /> Name of individual or corn pany: 6dA4;16--2- J6?1 0 4//;�I Phone: <br /> government unit: 9 <br /> vocal govei '00� Phone: <br /> Local government unij.address: zip: <br /> Any defective park of this system shall be repaired, replaced,or removed pursuant to SPS 383.51 (1),Wisc.Admin. <br /> Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383,Wisc.Admin.Code. <br /> No product for chemical or physical restoration of the POWTS may be used unless approved by the department in <br /> accordance with SPS 384,Wisc.Admin. Code. <br /> in the event that any failed treatment component of this POWTS cannot be repaired, it shall be replaced pursuant io <br /> a plan submitted to the appropriate agency for review and approval. A failed in-ground dispersal component may be <br /> abandoned and replaced by a code-complying dispersal component in a pre-determined area of suitable soils. <br /> 5 stem AbandonmaM <br /> if use of this POWTS is discontinued, it shall be abandoned in accordance with SPS 383.33,Wisc.Admin.Code. <br />