Laserfiche WebLink
PAGE 4OF4 <br /> In-ground Gravity Management Plan <br /> IMPORTANT: <br /> The owner of*,isc+irs9round"viky eyotom ah"be rooponaibre for ift perpetuW oper"cm sect nuteMat►onoe p�urouw*io <br /> requirerm is of WS M-384,Wisc.Admin.Code. Pursuant to SPS 383.52(2).WOM Adrrun.Code,lids system Shan <br /> be considered a hesnan health hazard if not maintained in accordance with this approved management Plan. <br /> FuNremrcrre,so inspection and mairiterranc:e activities shd be performed by a registered POWTS NWk tairrer in <br /> accordance with SPS 383.52(3).Vftr.Admin.Code. <br /> &Minn DhOMW Area OmadnaU nft <br /> Design Flow a �:5'0 gpd: BCC6:9 2201 rtr�9i�- ; TSS S 150 rngL4; FOGS 30 n*C <br /> Inspection Cho-Ckftt P�E/ t EVERY 3 YEARS <br /> o type of use <br /> o age of system <br /> o nuisanoe factors(is.odom user complaints,oft) <br /> o medranical malfunction(i.a.pumps,valves.Omittftw floats,eta) <br /> o material fatigue(i.e.,leaks.br+eelas.corrosion,etc.) <br /> o solids volume in anaerobic treatment terdc(s)and any Sian appurtenanoe(s)(La,dishfttion!droop boxes) <br /> o neglect or improper use(i.e..s weeding deep capacities,prohibited activities,eirz) <br /> o extent of ponding in dean cell prior to dosing <br /> o dosing Weaularities-if a ble 0 a.,pump re-c�float switch settings,eta) <br /> o elechical components-if q*Uc d*(Le.,wiring,connections,switches,contivA,timers,steams,eta) <br /> o distritam lateral or lateral onfice plugging (measure lateral distal pressure—compare to design won) <br /> o surface discharges of effluent or sewage track-up into structim served <br /> Maintnce Check_Iist MAINTAIN EVERY 3 YEARS(or when necessary) <br /> o &=and dam jEft)steal be Pumped by a certBed septage servicing operator ioenrsa under s.281.48 Vft <br /> Stets,when to volume of sow in the tan"exceeds orw4lrlyd(113)the liquid volume of the tanigs)or <br /> as urged by local orrliniince. Disposal of contents shalt be ptrrsuarut to NR 113.Wiac.Admin.Code. <br /> o !Ago shall be inspected every 3 years and shall be cleaned when necessary to remove any <br /> ac mumdated solids according to manufacturer's ems. A semclrg period WH alweya be greater than 12 <br /> months. <br /> System maintenance reports shall be submitted to the proper local government un0 In accordance wkh <br /> SPS 30M Wise.Adn*L Code. Report arty component facture or nratfunetlon in <br /> Name dindividual ofcaompony: C-o�-y /Ac G51xA� u.A�P�r:f/C� Phone: A5-- 14,6— t}!j <br /> Local al government urn BuRitl ear Prone: <br /> Local goverrrnent unit address_ �' /y, TA.;J z� f87Z <br /> Any defective part of this system$hag be repaired,replaced,or removed pursuant to SPS 383.51 (1),Wdr—Admin. <br /> Code.Repair or replacement of failed or malknictioning components shah comply with SPS 383,Vftc.Admin.Code. <br /> No product for ctremicol or physical restoration of the POWTS may be used unless approved by the departs to <br /> accordance with SPS 364,VVtsc.Admin.code. <br /> Contlnoenc y Plait <br /> In the event that airy failed treatment component of thia POWTS cannot be ram,it shah be replaced pursuant to <br /> a plan submitted to the appropriate agency for review and approval. A failed in-ground dispersal component may be <br /> aban&ned and replaced by a code-caraph� 6wersel wmPorw►t in e pre-debwmned arse of subtle ask, <br /> H use of this POWTS is d eel, it shall be abendoned in accordance with SPS 383.33,Wisc.A+drran.Code. <br />