Laserfiche WebLink
PAGE 4 ©F4 <br /> In-ground Dosed-Gravity Management Plan <br /> IMPORTANT: <br /> The owner of this in-ground dosed-gravity system shall be responsible for its perpetual operation and maintenance <br /> pursuant to requirements of SPS 382-384,Wisc.Admin. Code. Pursuant to SPS 383.52(2),Wisc.Admin.Code,this <br /> system shall be considered a human health hazard if not maintained in accordance with this approved management <br /> plan. Furthermore,all inspection and maintenance activities shall be performed by a registered POWTS Maintainer in <br /> accordance with SPS 383.52(3),Wisc.Admin. Code. <br /> Maximum Dispersal Area Ooeratina Limits: <br /> Design Flow= 750 gpd; BODs 5 220 mgC; TSS 5150 mgC; FOGS 30 mgL-' <br /> Inspection Checklist INSPECT EVERY 3 YEARS <br /> o type of use <br /> o age of system <br /> o nuisance factors(i.e. odors, user complaints,etc.) <br /> o mechanical malfunction(i.e., pumps,valves, switches,floats,etc.) <br /> o material fatigue(i.e.,leaks, breaks, corrosion, etc.) <br /> o solids volume in anaerobic treatment tank(s)and any distribution appurtenance(s)(i.e.,distribution/drop boxes) <br /> o neglect or improper use(i.e.,exceeding design capacities, prohibited activities, etc.) <br /> o extent of ponding in distribution cell prior to dosing <br /> o dosing irregularities-if applicable(i.e.,pump re-cyc ing,float switch settings, etc.) <br /> o electrical components-if applicable(i.e.,wiring,connections, switches,controls,timers, alarms, etc.) <br /> o distribution lateral or lateral orifice plugging (measure lateral distal pressure—compare to design specification) <br /> o surface discharge of effluent or sewage back-up into structure served <br /> Maintenance Checklist MAINTAIN EVERY 3 YEARS(or when necessary) <br /> o Septic and dose tankfsl shall be pumped by a certified septage servicing operator licensed under s. 281.48 Wis. <br /> Slats.when the volume of solids in the tank(s)exceeds one-third(113)the liquid volume of the tank(s)or <br /> as required by local ordinance. Disposal of contents shall be pursuant to NR 113,Wisc.Admin.Code. <br /> o Effluent filtertsl shall be inspected every 3 years and shall be cleaned when necessary to remove any <br /> accumulated solids according to manufacturer's specifications. A servicing period will always be greater than 12 <br /> months. <br /> System maintenance reports shall be submitted to the proper local government unit in accordance with <br /> SPS 383.55 Wisc.Admin, Code. Report any component failure or malfunction to: <br /> Name of individual or company: Schmitz Septic 8r Excavating LLC Phi_ 715-468-2434 <br /> Local government unit: Burnett County Zoning Phone: 715-349-2138 <br /> Local government unit address: Siren W1 ZIP: 54872 <br /> Any defective part of this system shall be repaired, replaced, or removed pursuant to SPS 383.51 (1),Wisc.Admin. <br /> Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383,Wisc.Admin.Code. <br /> No product for chemical or physical restoration of the POWTS may be used unless approved by the department in <br /> accordance with SPS 384,Wisc.Admin. Code. <br /> Contingency Plan <br /> In the event that any failed treatment component of this POWTS cannot be repaired, it shall be replaced pursuant to <br /> a plan submitted to the appropriate agency for review and approval. A failed in-ground dispersal component may be <br /> abandoned and replaced by a code-complying dispersal component in a pre-determined area of suitable soils. <br /> System,Abandonment <br /> If use of this POWTS is discontinued, it shall be abandoned in accordance with SPS 383.33,Wisc.Admin. Code. <br />