Laserfiche WebLink
PLOT PLAN REQUIREMENT <br /> A plot plan drawing is required to be submitted along with this application. The plot plan drawing shall either be drawn to <br /> scale,in feet,or be FULLY dimensioned in feet. Please note the scale on the drawing,if one is used.The plot plan drawing shall <br /> be on letter or legal size paper with North being at the top of the page. (Make sure all relevant items below are shown-check <br /> each relevant box): <br /> ✓ ✓ 1/ <br /> Property lines,road right-of-ways,and road centerlines including distances to property lines,road right-of-ways and road <br /> centerlines for all existing and proposed structures on the parcel <br /> "Ordinary High Water Mark(OHWM)when existing,and distances to it from all existing and proposed structures <br /> ❑ Provide Total Impervious Surface(IS)Percentages including new existing and proposed development.This standard is only <br /> applicable if the proposed project is within 300'of the OHWM of any body of water. You only need to count the impervious <br /> 'surfaces that are partially or entirely within 300' of the OHWM of a body of water. To calculate,divide the total existing and <br /> A) proposed impervious surfaces in square feet by the total square footage of the parcel above the OHWM.Then multiply that number <br /> 1_ by 100 to get a percentage.Example:2,500 square feet of IS within 300'of OHWM=43,560 square foot parcel x 100= 5.74% <br /> impervious surfaces(1 acre=43,560 square feet).Impervious surfaces include but are not limited to:building roofs,sidewalks, <br /> decks,patios,cement/asphalt/gravel driveways,etc.If the proposed project exceeds 15%impervious surface,mitigation is required. <br /> If the impervious surface exceeds 30%,you will need to apply for a variance.NOTE: If you are only replacing existing legally <br /> built structures within the same footprint,no impervious surface calculations are needed. Land Services reserves the right to <br /> require a survey when there are disputes over this calculation. <br /> Floodplain and wetland areas/boundaries and distances to them from all existing and proposed structures <br /> xis ing andproposed struc es on the par el i udin all decks/porches/walkways/etc;must show dimensions for ALL items <br /> G A , 3x3.( OA/ 4 <br /> "Existing and proposed sanitary system and wel locations including distances to existing and pr posed structures <br /> U Heights f all existi nd p o ose stru4ctures NOT? 1eight ism sjred om lowest adjacent grade to the highest roof peak <br /> #4-91^1 i D C9�N' tr , <br /> qtli <br /> (Coimercial/Indu t al lnly)Ex s ing and proposed parkin;muss?ihi imensions and proposed number of stalls <br /> xistin and ro osed drivewa s; must show dimensions and width NOTE: Driveways must have a cleared width of 20 ft and a <br /> g P P Y � Y <br /> cleared height of 13 ft,and sufficient turn-around space for rescue services to utilize <br /> worth arrow /I <br /> vegetation proposed to be removed or disturbed - U at.,•LrwIIS h 5msffi tv4u <br /> i , re . Na��« Pim <br /> O—Location and extent of proposed filling/grading I 2,/l s 47/ f-" / u', des- e.:.0�j,,�r g4fary <br /> ❑ Location and type of erosion control measures <br /> , construction plans shall be submitted with this application for all Commercial/Industrial related construction. <br /> V'� - Construction plans shall show interior layout,exterior profiles and exterior heights. <br /> L13• Proposed building/structure locations must be staked prior to submitting this application to the Land Services Department. <br /> County staff will do an onsite visit to verify site conditions. If all proposed structures(including decks,patios,retaining <br /> walls,etc)are not staked upon County staff visit,the permit may not be approved and may be returned to the applicant. <br /> V.-1i all existing structures on the parcel are not shown and dimensioned on the plot plan drawing,the permit may not be <br /> issued and may be returned to the applicant. <br /> Page 2 of 4 <br /> Burnett County, WI Land Use Application- Rev 12/2020 <br />