Laserfiche WebLink
CONTINGENCY PLAN MANAGEMENT PLAN DOMESTIC WASTEWATER <br /> - C INGROUND SYSTEM PURSUANT SPS 83.54 ADM. CODE POWTS <br /> SHALL INCLUDE INFO, AND PROCEDURES <br /> FOR MAINTAINING THE SYSTEM WITHIN <br /> ----- AT-GRADE SYSTEM CURRENT CODES.THIS MGMT PLAN COMPLIES <br /> WITH SPS. 83.54 WI ADMIN. CODE AND THE <br /> INGROUND SOIL OBSORPTION COMPONENT <br /> ---- MOUND SYSTEM MANUAL SBD-10705-P (N.01/01 VERSION 2) <br /> ----- HOLDING TANK <br /> TABLE 1 <br /> -.�ALTERNATE AREA PROVIDED AS NUMBER OF BEDROOMS 2- <br /> EVIDENCED WITH ADDED PITS/BORINGS DESIGN FLOW-PEAK(GPD)�3 0 <br /> � J.6 fe ESTIMATED FLOW-AVG. (GPD) ZO <br /> J �C�i SEPTIC TANK CAPACITY (GAL) Zoo Soo Ci 001a capsized) <br /> ----- MOUND SYSTEM REPLACEMENT OF CELL/DRAINFIELD SIZE <br /> DRAINFIELD WITHIN EXISTING LOCATION <br /> ----- REPLACE EXISTING HOLDNG TANK TABLE 2 <br /> WITH NEW TANK DESIGN FLOW PEAK(TANK) 300 <br /> ----- ALTERNATE AREA DOES NOT EXIST CELL/FEILD COMPONENT 150 .s.r-T. <br /> BY LACK OF AREA. HOLDING TANK OR <br /> NEW TECHNOLOGY SYSTEM TO BE <br /> INSERTED INTO EXISTING SYSTEM <br /> SEPTIC TANK <br /> THE SEPTIC TANK SHALL BE MAINTAINED BY A CERTIFIED TO SERVICE TANKS UNDER S281.48 STATS. <br /> THE CONTENTS OF THE TANK SHALL BE DISPOSED OF IN ACCORDANCE WITH NR113 WI.ADM. CODE <br /> THE OPERATING CONDITION OF THE FILTER SHALL BE ASSESSED ONCE EVERY YEAR BY CLEANING. <br /> PUMPING AND/OR INSPECTION OF TANKS IS REQUIRED EVERY 3 YEARS.THE OUTLET BAFFLE FILTER <br /> SHALL BE CLEANED AS NEEDEDTO ENSURE PROPER OPERATION OF POWTS SYSTEM.THE FILTER <br /> CARTRIDGE SHOULD NOT BE REMOVED UNLESS PROVISIONS ARE MADE TO SOLIDS>THAN 1/8" <br /> REMAIN IN TANK. THE SEPTIC TANK SHALL HAVE ITS CONTENTS REMOVED WHEN THE VOLUME OF <br /> SLUDGE AND SCUM IN THE TANK EXCEEDS 1/3 THE LIQUID CAPACITY OF THE TANK. IF CONTENTS ARE <br /> NOT REMOVED FAILURE OF SYSTEM MAY RESULT. <br /> START UP AND OPERATION <br /> REPLACEMENT POWTS REQUIRE NORMAL USE TO ACTIVATE TANK(DO NOT USE CHEMICALS) <br /> _,_,orNEW CONSTRUCTION: TANKS SHOULD BE INSPECTED FOR PRESENCE OF PAINTING OR CHEMICALS <br /> (DRYWALL DUST)THESE CHEMICALS WILL IMPEDE OR DAMAGE POWTS <br /> IF CONCENTRATIONS ARE DETECTED TANK MUST BE PUMPED BY LICENSED PUMPER <br /> DO NOT DRIVE OR PARK AUTOS OVER TANKS OR CELLS. <br /> DO NOT DRIVE OR DISTURB THE AREA WITHIN 15 FT OF THE DOWNSLOPE TOES OF ANY MOUND OR AT- <br /> GRADE SOIL ABSORPTION AREA <br /> ABANDONMENT:WHEN THE POWTS SYSTEM IS REMOVED FROM SERVICE THE COMPONENT MUST BE <br /> ABANDONED IN COMPLIANCE WITH COMM. 83.33 WI ADM. CODE <br /> p ALL PIPING MUST BE DISCONNECTED AND OPENINGS SEALED, CONTENTS MUST BE REMOVED AND <br /> f, PROPERLY DISPOSED OF BY SERVICING OPERATOR AND TANKS/PITS COVERS ARE TO BE REMOVED <br /> \ SAND VOID SPACE FILLED WITH SOIUSOLID MATERIAL. <br /> �( Page 3 of 8 <br /> Cj� eN Pmvx B04y, <br /> R xv <br />