Laserfiche WebLink
PAGE 4 OF 4 <br /> h-c round Gravity Managlient Ran <br /> dlOdPORTANT.' <br /> The owner of this in-ground gravity system shall be responsible for its perpetual operation and maintenance pursuant'to <br /> requirements of SPS 382-384,Wisc.Admin. Code. Pursuant to SPS 383.52(2),Wisc.Admin.Code,this system shad <br /> be considered a human health hazard if not maintained in accordance with this approved management plan. <br /> Furthermore,all inspection and maintenance activities shall be performed by a registered P*WTS maintainer in <br /> accordance with SPS 383.52(3),Wisc.Admin. Code. <br /> fiairrmars,M Area 0 ar2_ 11 <br /> Deakgrn Flow] ! 5-6 gpd; BOD5 5.220 mgL-1; TSS 51150 mgCl; Fici 5 30 rtrkgL- <br /> :icaosAcazi Cctlie PHSPECT EVE[':If 3 YEA1-,S <br /> o type of use <br /> o age of system <br /> o nuisance factors(i.e. odors, user complaints, etc.) <br /> o mechanical malfunction(i.e., pumps,valves, switches,floats, etc.) <br /> o material fatigue(i.e., leaks, breaks, corrosion, etc.) <br /> o solids volume in anaerobic treatment tank(s)and any distribution appurtenance(s)(i.e.,distribution/drop boxes) <br /> o neglect or improper use(i.e., exceeding design capacities, prohibited activities, etc.) <br /> o extent of ponding in distribution cell prior to dosing <br /> o dosing irregularities-if applicable(i.e., pump re-cycling,float switch settings, etc.) <br /> c electrical components-if applicable(i.e.,wiring, connections, switches, controls,timers, alarms, etc.) <br /> c distribution lateral or lateral orifice plugging (measure lateral distal pressure-compare to design specification) <br /> o surface discharge of effluent or sewage back-up into structure served <br /> Ytk-ant,,,,Elance Chack5fia.c Do'dAfiNTAN EVERY 3 YlEA!S (or when necessary) <br /> o ptic and dose tank(1)shall be pumped by a certified septage servicing operator licensed under s.281.48 Wis. <br /> Stats.when the volume of solids in the tank(s)exceeds one-third(1/3)the liquid v*Iume of the teak(s)or <br /> as required by local ordinance. Disposal of contents shall be pursuant to NR 113,Wisc.Admin. Code. <br /> o E-ffiluent ffiken(s))shall be inspected every 3 years and shall be cleaned when necessary to remove any <br /> accumulated solids according to manufacturer's specifications. A servicing period will always be greater than 12 <br /> months. <br /> System '.,,laifittenance reports small be subcrni.ated to the proper local government unit in accordance with <br /> SP 383.55 Wisc.Admin. Code. Report any component failure or malfunction to: <br /> Name of individual or company: 6d 4c-/-e_._ Phone: <br /> Locai government unit: /Sci/IA.) � 'z/- j <br /> Locei government unit address: e_pj / ZIP: .54/g7..2 <br /> Any defective part of this system shall be repaired,replaced, or removed pursuant to SPS 383.51 (1),Wisc.Admin. <br /> Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383,Wisc.Admin. Code. <br /> No product for chemical or physical restoration of the POWTS may be used unless approved by the department in <br /> accordance with SPS 384,Wisc.Admin. Code. <br /> Pte <br /> in the event that any failed treatment component of this POWTS cannot be repaired, it shall be replaced pursuant to <br /> a pian submitted to the appropriate agency for review and approval. A failed in-ground dispersal component may be <br /> abandoned and replaced by a code-complying dispersal component in a pre-determined area of suitable soils. <br /> arsym Absia6. <br /> if use of this POWTS is discontinued, it shall be abandoned in accordance with SPS 383.33,Wisc.Admin. Code. <br />