PAGE 4 OF 4
<br /> h-c round Gravity Managlient Ran
<br /> dlOdPORTANT.'
<br /> The owner of this in-ground gravity system shall be responsible for its perpetual operation and maintenance pursuant'to
<br /> requirements of SPS 382-384,Wisc.Admin. Code. Pursuant to SPS 383.52(2),Wisc.Admin.Code,this system shad
<br /> be considered a human health hazard if not maintained in accordance with this approved management plan.
<br /> Furthermore,all inspection and maintenance activities shall be performed by a registered P*WTS maintainer in
<br /> accordance with SPS 383.52(3),Wisc.Admin. Code.
<br /> fiairrmars,M Area 0 ar2_ 11
<br /> Deakgrn Flow] ! 5-6 gpd; BOD5 5.220 mgL-1; TSS 51150 mgCl; Fici 5 30 rtrkgL-
<br /> :icaosAcazi Cctlie PHSPECT EVE[':If 3 YEA1-,S
<br /> o type of use
<br /> o age of system
<br /> o nuisance factors(i.e. odors, user complaints, etc.)
<br /> o mechanical malfunction(i.e., pumps,valves, switches,floats, etc.)
<br /> o material fatigue(i.e., leaks, breaks, corrosion, etc.)
<br /> o solids volume in anaerobic treatment tank(s)and any distribution appurtenance(s)(i.e.,distribution/drop boxes)
<br /> o neglect or improper use(i.e., exceeding design capacities, prohibited activities, etc.)
<br /> o extent of ponding in distribution cell prior to dosing
<br /> o dosing irregularities-if applicable(i.e., pump re-cycling,float switch settings, etc.)
<br /> c electrical components-if applicable(i.e.,wiring, connections, switches, controls,timers, alarms, etc.)
<br /> c distribution lateral or lateral orifice plugging (measure lateral distal pressure-compare to design specification)
<br /> o surface discharge of effluent or sewage back-up into structure served
<br /> Ytk-ant,,,,Elance Chack5fia.c Do'dAfiNTAN EVERY 3 YlEA!S (or when necessary)
<br /> o ptic and dose tank(1)shall be pumped by a certified septage servicing operator licensed under s.281.48 Wis.
<br /> Stats.when the volume of solids in the tank(s)exceeds one-third(1/3)the liquid v*Iume of the teak(s)or
<br /> as required by local ordinance. Disposal of contents shall be pursuant to NR 113,Wisc.Admin. Code.
<br /> o E-ffiluent ffiken(s))shall be inspected every 3 years and shall be cleaned when necessary to remove any
<br /> accumulated solids according to manufacturer's specifications. A servicing period will always be greater than 12
<br /> months.
<br /> System '.,,laifittenance reports small be subcrni.ated to the proper local government unit in accordance with
<br /> SP 383.55 Wisc.Admin. Code. Report any component failure or malfunction to:
<br /> Name of individual or company: 6d 4c-/-e_._ Phone:
<br /> Locai government unit: /Sci/IA.) � 'z/- j
<br /> Locei government unit address: e_pj / ZIP: .54/g7..2
<br /> Any defective part of this system shall be repaired,replaced, or removed pursuant to SPS 383.51 (1),Wisc.Admin.
<br /> Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383,Wisc.Admin. Code.
<br /> No product for chemical or physical restoration of the POWTS may be used unless approved by the department in
<br /> accordance with SPS 384,Wisc.Admin. Code.
<br /> Pte
<br /> in the event that any failed treatment component of this POWTS cannot be repaired, it shall be replaced pursuant to
<br /> a pian submitted to the appropriate agency for review and approval. A failed in-ground dispersal component may be
<br /> abandoned and replaced by a code-complying dispersal component in a pre-determined area of suitable soils.
<br /> arsym Absia6.
<br /> if use of this POWTS is discontinued, it shall be abandoned in accordance with SPS 383.33,Wisc.Admin. Code.
<br />
|