Laserfiche WebLink
v <br /> Private Onsite Wastewater Treatment System Management Plan <br /> Septic Tank And Gravity In-Ground Soil Absorption Component <br /> Pursuant to Comm 83.54 Wis. Adm. Code each Private Onsite Wastewater Treatment <br /> System (POWTS) shall Include information and procedures for maintaining the system within <br /> the parameters of Comm 83 and 84, and the conditions of approval by the department, agent, <br /> or governmental unit. The approved plans and permits for system are on file at the county <br /> zoning or health department. <br /> This management plan complies with Comm 83.54, Wis. Adm. Code, and the In-Ground <br /> Soil Absorption Component Manual for Private Onsite Wastewater Treatment Systems SBD- <br /> 10567-P (R.6/99). <br /> Table 1: System Desi n Specifications <br /> SanitaEy Permit Number <br /> Number of Bedrooms <br /> Design Flow- Peak d O <br /> Estimated Flow-Average d _ <br /> Septic Tank Capacity al 7S[� <br /> Soil Absorption Compi SizeSft 3 <br /> Type of Wastewater Domestic <br /> Table 2: Soil Absorption Component-Limits of R®liable Operation <br /> _^ <br /> Septic Tank Component Soil Absorption Component <br /> Design Flow- Peak d --300 CO <br /> Maximum Influent Particle Size in NA 1/8 <br /> Maximum BOD (Mg/L NA 220 <br /> Maximum TSS mg/L NA 150 <br /> Maximum FOG NA 30 <br /> Table 3: Maintenance Schedule <br /> Septic Tank I Inspect and/or service once every 3 years <br /> Outlet Filter _ Should Inspect once a year and clean once every 3 years <br /> Soil Absorption Com anent I Inspect once eve 3 years <br /> Seutic Tank <br /> The septic tank shall be maintained by an individual certified to service septic tanks <br /> under s. 281,48, Stats. The contents of the septic tank shall be disposed of in accordance with <br /> NR 113, Wis. Adm. Code (Servicing Septic or Holding Tanks, Pumping Chambers, Grease <br /> Interceptors, Seepage Beds, Seepage Pits, Seepage Trenches, Privies, or Portable <br /> Restrooms). <br /> The operating condition of the septic tank and outlet filter shall be assessed at least <br /> once every 3 years by inspection. The outlet filter shall be cleaned as necessary to ensure <br /> proper operation. The filter cartridge should not be removed unless provisions are made to <br /> retain solids in the tank that may slough off the filter when removed from its enclosure. If the <br /> filter is equipped with an alarm, the filter shall be serviced if the alarm is activated continuously. <br /> Intermittent filter alarms may indicate surge flows or an impending continuous alarm. The <br /> septic tank shall have its contents removed when the volume of scum and sludge in the tank <br /> exceeds 1/3 the liquid volume of the tank. If the contents of the tank are not removed at the <br /> 'f�Nl � GJ�4lLS <br />