Laserfiche WebLink
PAGE 4 OF 4 <br /> .100thing Lnk Managemnt <br /> kilr A iikriP' <br /> Me owner of this holding tank(s)shall be responsible for its perpetual operation and maintenance pursuant to <br /> requirements of SPS 382-384,Wise,Adrnin, Code. Pursuant to SPS 383.52(2),Wisc.Admin.Code,this holding tank(s) <br /> shall be considered a human health hazard if not maintained in accordance with this approved management plan. <br /> Furthemiore,all inspection and maintenance activities shall be performed by a registered POWS Haintaine,5'in <br /> accordance with SPS 383.52(3),Wisc.Admin, Code. <br /> -1.'scdu-saate.z;J Daly Wastewater Fkm 0.100 god <br /> '7.03ST,OGCVaLTD. Chectlast [INSPECT EVERY 3 YEARS <br /> O type of use <br /> o age of system <br /> O nuisance factors(i.e. odors, user complaints, etc.) <br /> o mechanical malfunction(La, pumps,valves, switches,floats, etc.) <br /> o material fatigue(i.e.,leaks, breaks, corrosion, etc.) <br /> o neglect or improper use(i.e., a4oeeding design capacities, prohibited activities, etc.) <br /> O electrical components(Le.,wiring, connections, switches,controls,timers, alarms, etc.) <br /> o surface discharge of effluent or sewage back-up into structure served <br /> SERVOCING EQUENCY <br /> o The tank(s)shall be pumped by a certified septage servicing operator licensed under s.281.43 Wise, Stets. <br /> when the wastewater in the tank(s3)reaches a level of one Not bellow the inlet invert of the tarilge). <br /> Disposal of contents shall be pursuant to NR 113,Wisc.Admin.Code. <br /> Tank pumping reioorts shall be subraitte,d to the proper local government unit in accwrdaroce with SIPS 333.55 <br /> Admin,Code. Report any component'failure or malfunction to: <br /> Nama of individual or company: GeAe.-- kuri-AD 1).71 Phone: <br /> Local government unit: laisit) 0/0/ c <br /> Phone: -.75/ — Jo9 <br /> Local government unit address: -Sire...) ZIP: _63/,*77 <br /> An defective part of this system shall be repaired, replaced, or removed pursuant to SPS 383.51 (1),Wisc.Admin, <br /> Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383,Wisc.Admin,Code. <br /> No product for chemical or physical restoration of the POWTS may be used unless approved by the department:in <br /> accordance with SPS 384,Wisc,Admin..Code, <br /> S..;,ontijapief_Ektp <br /> in the event that any failed component of this holding tank(s)cannot be repaired,it shall be replaced pursuant to a <br /> plan submitted to the appropriate agecy for review and approval. <br /> Svaistil/Oarpdammeri <br /> if use of this tank(s)is discontinued,it shall be abandoned in accordance with SPS 383.33,Wisc.Admin. Coda. <br />