Laserfiche WebLink
POWTS OWNER'S MANUAL & MANAGEMENT PLAN Page 14 of S <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner 4.L_C (t&o NeJso„ Septic Tank Capacity /o o gal 0 N <br /> Permit# 559000 Septic Tank Manufacturer Lull 0 N <br /> DESIGN PARAMETERS Effluent Filler Manufacturer &07-0m 0 NA <br /> Number of Bedrooms O NA Effluent Filter Model TO E2L 0 NA <br /> Number of Commercial Units %i'NA Pump Tank Capacity al 53-NA <br /> Estimated flow(average) 3 W gal/day Pump Tank Manufacturer RNA <br /> Design flow(peak), (Estimated x 1.5) gal/day Pump Manufacturer E(NA <br /> Soil Application Rate gal/day/ft' Pump Model Md NA <br /> Influent/Effluent Quality Monthly average' Pretreatment Unit 0 NA <br /> Fats, Oil & Grease (FOG) 530 mg/L 0 Sand/Gravel Filler 0 Peat Filter <br /> Biochemical Oxygen Demand (BOD,) 5220 mg/L 0 Mechanical Aeration ❑Wetland <br /> Total Suspended Solids (TSS) 5150 mg/L 0 Disinfection 0 Other: <br /> Manufacturer <br /> Pretreated Effluent Quality 0 NA Monthly average" Dispersal Cell(s) <br /> Biochemical Oxygen Demand (BODS) 530 mg/L 0 In-ground (gravity) 0 In-ground (pressurized) <br /> Total Suspended Solids (TSS) 530 mg/L 0 At-grade 0 Mound <br /> Fecal Coliform (geometric mean) 510"cfu/100ml 0 Drip-line 0 Other: <br /> Maximum Effluent Particle Size ya inch diameter Values typicalfor domestic(nontmmerciap wastewater and <br /> septic lank effluent. <br /> MAINTENANCE SCHEDULE Values typical for preheated wastewater. <br /> Service Event Service Frequency <br /> Inspect condition of tank(s) At least once every 3 0 months ®'year(s) (Maximum 3 yrs.) <br /> Pump out contents of tank(s) When combined sludge and scum equals one-third ('h)of tank volume <br /> Inspect dispersal cellist At least once every 3 0 months 2year(s) (Maximum 3 yrs.) <br /> Clean effluent filter At least once every ) 0 months eyear(s) <br /> Inspect pump, pump controls& alarm At least once every 0 months 0 years) ETNA <br /> Flush laterals and pressure test At least once every 0 months 0 year(s) E'NA <br /> Other: At least once every 0 months 0 year(s) ®'NA <br /> Other. At least once every 0 months 0 year(s) BNA <br /> MAINTENANCE INSTRUCTIONS: Inspections of tanks and dispersal cells shall be made by an individual carrying one of the <br /> following licenses or certifications: Master Plumber; Master Plumber Restricted Sewer; POWTS Inspector; POWTS Maintainer; <br /> Septage Servicing Operator. Tank inspections must include a visual inspection of the tank(s) to identify any missing or broken <br /> hardware, identify any cracks or leaks, measure the volume of combined sludge and scum and to check for any back up or <br /> ponding of effluent on the ground surface. The dispersal cell(s) shall be visually inspected to check the effluent levels in the <br /> observation pipes and to check for any ponding of effluent on the ground surface. The ponding of effluent on the ground surface <br /> may indicate a failing condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any tank equals one-third (h)or more of the tank volume, the entire <br /> contents of the tank shall be removed by a Septage Servicing Operator and disposed of in accordance with ch. NR 113, <br /> Wis. Adm. Code. <br /> The servicing of effluent filters, mechanical or pressurized POWTS components, pretreatement components, and any other <br /> maintenance or monitoring at intervals of 12 months or less shall be conformed by a certified POWTS Maintainer. <br />