PAGE 4 ' JIP 4
<br /> n jjound1 Gravity Man gem -n°, Flan
<br /> The owner of this in-ground gravity system shall be responsible for its perpetual operation and maintenance pursuant to
<br /> requirements of SPS 382-384,Wisc.Admin. Code. Pursuant to SPS 383.52(2),Wisc.Admin.Code, this system shall
<br /> be considered a human health hazard if not maintained in accordance with this approved management plan.
<br /> Furthermore,all inspection and maintenance activities shall be performed by a registered POWTS I laintainer in
<br /> accordance with SPS 383.52(3),Wisc.Admin. Code.
<br /> EXltinaam [ lapereaB Area Operrat nq LonJts:
<br /> Desk in Flow_ 300 j d; tOD5 5.220 angL'1; TSS <_ 150 angL4; F(e)G 5 SO cy,-
<br /> lnspectii•,n Checklist INSPECT EVE!'Y 3 YE ,"-°S
<br /> o type of use
<br /> o age of system
<br /> o nuisance factors(i.e. odors, user complaints, etc.)
<br /> mechanical malfunction (i.e., pumps,valves, switches,floats, etc.)
<br /> o material fatigue(Le., leaks, breaks, corrosion, etc.)
<br /> o solids volume in anaerobic treatment tank(s)and any distribution appurtenance(s)(i.e.,distribution i drop boxes)
<br /> o neglect or improper use(i.e., exceeding design capacities, prohibited activities, etc.)
<br /> o extent .'r ponding in distribution cell prior to dosing
<br /> o dosing irregularities-if applicable(i.e., pump re-cycling,float switch settings, etc.)
<br /> o electrical components-if applicable(i.e.,wiring, connections, switches, controls, timers, alarms, etc.)
<br /> o distribution lateral or lateral orifice plugging (measure lateral distal pressure—compare to design specification)
<br /> o surface discharge of effluent or sewage back-up into structure served
<br /> YtAaahltenance Cki9ecwlii is EdAKITABH EVERY 3 YE^,FSS (or when necessauy)
<br /> o Septic and dose tankfs)shall be pumped by a certified septage servicing operator licensed under s. 281.4 6 Wis.
<br /> Stets.when the volume of solids in the tank(s)exceeds one-third(1/3)the liquid v.,Dunn of the tanh(a) or
<br /> as required by local ordinance. Disposal of contents shall be pursuant to NR 113,Wisc.Admin. Code.
<br /> o Effluent LUterfs)shall be inspected every 3 years and shall be cleaned when necessary to remove any
<br /> accumulated solids according to manufacturer's specifications. A servicing period will always be greater than 12
<br /> months.
<br /> System e alntenance reports shall be submitted to the proper l;•;cal government unit in accordance'ts with
<br /> SPS 383.55 Wisc.Admin. Cw>de. Report any component failure or malfunction to: /
<br /> ."arm e of individual or company: G� 4c/� tL-(f /i 1 4t) Phone: 3yq Z.2 1b._...__--
<br /> Locai government unit: $4,r•t) Z o Phone: 397 o?/d 7
<br /> ,.cc...EA government unit address: S.'/`42-i0 4-41 Z ZIP: .5-` e72
<br /> Arty defective part of this system shall be repaired, replaced,or removed pursuant to SPS 383.51 (1),Wisc.Admin,
<br /> Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383,Wisc.Admin.Code.
<br /> No product for chemical or physical restoration of the POWTS may be used unless approved by the department in
<br /> accordance with SPS 384,Wisc.Admin.Code.
<br /> c c ogin_ ency Plan
<br /> In the event that any failed treatment component of this POWTS cannot be repaired, it shall be replaced pursuant to
<br /> a plan submitted to the appropriate agency for review and approval. A failed in-ground dispersal component may be
<br /> abandoned and replaced by a code-complying dispersal component in a pre-determined area of suitable soils.
<br /> , edn i"h and.na ienu
<br /> if use of this POWTS is discontinued, it shall be abandoned in accordance with SPS 383.33,Wisc.Admin. Code.
<br />
|