Laserfiche WebLink
PAGE 4 ' JIP 4 <br /> n jjound1 Gravity Man gem -n°, Flan <br /> The owner of this in-ground gravity system shall be responsible for its perpetual operation and maintenance pursuant to <br /> requirements of SPS 382-384,Wisc.Admin. Code. Pursuant to SPS 383.52(2),Wisc.Admin.Code, this system shall <br /> be considered a human health hazard if not maintained in accordance with this approved management plan. <br /> Furthermore,all inspection and maintenance activities shall be performed by a registered POWTS I laintainer in <br /> accordance with SPS 383.52(3),Wisc.Admin. Code. <br /> EXltinaam [ lapereaB Area Operrat nq LonJts: <br /> Desk in Flow_ 300 j d; tOD5 5.220 angL'1; TSS <_ 150 angL4; F(e)G 5 SO cy,- <br /> lnspectii•,n Checklist INSPECT EVE!'Y 3 YE ,"-°S <br /> o type of use <br /> o age of system <br /> o nuisance factors(i.e. odors, user complaints, etc.) <br /> mechanical malfunction (i.e., pumps,valves, switches,floats, etc.) <br /> o material fatigue(Le., leaks, breaks, corrosion, etc.) <br /> o solids volume in anaerobic treatment tank(s)and any distribution appurtenance(s)(i.e.,distribution i drop boxes) <br /> o neglect or improper use(i.e., exceeding design capacities, prohibited activities, etc.) <br /> o extent .'r ponding in distribution cell prior to dosing <br /> o dosing irregularities-if applicable(i.e., pump re-cycling,float switch settings, etc.) <br /> o electrical components-if applicable(i.e.,wiring, connections, switches, controls, timers, alarms, etc.) <br /> o distribution lateral or lateral orifice plugging (measure lateral distal pressure—compare to design specification) <br /> o surface discharge of effluent or sewage back-up into structure served <br /> YtAaahltenance Cki9ecwlii is EdAKITABH EVERY 3 YE^,FSS (or when necessauy) <br /> o Septic and dose tankfs)shall be pumped by a certified septage servicing operator licensed under s. 281.4 6 Wis. <br /> Stets.when the volume of solids in the tank(s)exceeds one-third(1/3)the liquid v.,Dunn of the tanh(a) or <br /> as required by local ordinance. Disposal of contents shall be pursuant to NR 113,Wisc.Admin. Code. <br /> o Effluent LUterfs)shall be inspected every 3 years and shall be cleaned when necessary to remove any <br /> accumulated solids according to manufacturer's specifications. A servicing period will always be greater than 12 <br /> months. <br /> System e alntenance reports shall be submitted to the proper l;•;cal government unit in accordance'ts with <br /> SPS 383.55 Wisc.Admin. Cw>de. Report any component failure or malfunction to: / <br /> ."arm e of individual or company: G� 4c/� tL-(f /i 1 4t) Phone: 3yq Z.2 1b._...__-- <br /> Locai government unit: $4,r•t) Z o Phone: 397 o?/d 7 <br /> ,.cc...EA government unit address: S.'/`42-i0 4-41 Z ZIP: .5-` e72 <br /> Arty defective part of this system shall be repaired, replaced,or removed pursuant to SPS 383.51 (1),Wisc.Admin, <br /> Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383,Wisc.Admin.Code. <br /> No product for chemical or physical restoration of the POWTS may be used unless approved by the department in <br /> accordance with SPS 384,Wisc.Admin.Code. <br /> c c ogin_ ency Plan <br /> In the event that any failed treatment component of this POWTS cannot be repaired, it shall be replaced pursuant to <br /> a plan submitted to the appropriate agency for review and approval. A failed in-ground dispersal component may be <br /> abandoned and replaced by a code-complying dispersal component in a pre-determined area of suitable soils. <br /> , edn i"h and.na ienu <br /> if use of this POWTS is discontinued, it shall be abandoned in accordance with SPS 383.33,Wisc.Admin. Code. <br />