Laserfiche WebLink
HOLDING TANK SPECIFICATIONS <br /> 2 Number of bedrooms <br /> Non-residential estimated flow(gpd) <br /> 2000.0 Minimum holding tank volume required (gal) <br /> Side A Side B Total <br /> 1250.0 I 750.0 I 2000.0 Proposed tank capacity (gal) <br /> Wieser Concrete Tank manufacturer <br /> 1250/750 Tank model number <br /> SJE Rhombus Alarm manufacturer <br /> Tank Alert 1 (101-01H) 120 VAC 'Alarm model number <br /> Tank Dimensions and Data Tank Anchor Calculations <br /> X for round tank 14860 lbs Weight of tank and cover <br /> 51.0 Liquid depth below inlet invert(in) 1.10 Safety factor <br /> 8.0 Maximum depth of soil cover(ft) 19636 lbs Weight of anchor required <br /> 66.0 Height(in) Outside 25.8 in Soil cover req. for anchor or <br /> 153.0 Length (in) Dimensions 4.8 yd' Concrete counter weight <br /> 86.0 Width (in) Only <br /> HOLDING TANK CROSS SECTION <br /> Electrical complies with NEC 300 and SPS 316 <br /> vent pipe manhole cover with <br /> locking device and <br /> warning label finished <br /> grade <br /> junction i I <br /> box <br /> $ 4"min. / <br /> 23 in. —,� 6"max. <br /> IG/ <br /> conduit <br /> _ sealed water 1Fr min <br /> tight — -r 1 <br /> thether --' <br /> /weight Note: All tank joints, and joints -' <br /> IG between tank openings and building sewer <br /> • service are sealed watertight. All inlet <br /> blind plug cD alarm on A piping g <br /> to seal pipe and vent materials comply <br /> outlet with SPS 384. Manholes with <br /> 90% Full 42.8 in locking device are typical for each <br /> manhole opening . <br /> Side A 1250.0 gal Side B 750.0 gal <br /> V <br /> 3 in.bedding under tank. Tank is anchored as necessary to negate buoyancy. <br /> Project: Joyce Holding Tank <br /> Page 2 of 4 <br />