Laserfiche WebLink
A plot plan drawing is required to be submitted along with this application. The plot plan drawing shall either be drawn with a <br /> scale between I"=20' and I"=50'by multiples of 10'or FULLY dimensioned. Please note the scale used on the drawing. If all <br /> distances are dimensioned a scale is not necessary.The plot plan drawing shall be on letter or legal size paper with North being <br /> at the top of the page. (Make sure all relevant items below are shown—check each relevant box): <br /> ❑ Property lines,road right-of-ways, and road centerlines including distances to property lines,road right-of-ways and road <br /> centerlines for all existing and proposed structures on the parcel <br /> ❑ Ordinary High Water Mark(OHWM)and distances to it from all existing and proposed structures; must show all within 200 ft of <br /> structures <br /> ❑ Floodplain and wetland areas/boundaries and distances to them from all existing and proposed structures;must show all within 200 <br /> ft of structures <br /> ❑ Proposed structures and their proposed locations including all decks/porches/walkways/etc;must show dimensions for ALL items <br /> ❑ Proposed sanitary system and proposed well location including distances to property lines,road right-of-ways and road centerlines <br /> ❑ Existing structures on the parcel including all decks/porches/walkways/etc and including any existing sanitary system and wells; <br /> must show dimension for ALL items <br /> ❑ Heights for all existing and proposed structures *Height is measured from lowest adjacent grade to the highest roof peak,heights <br /> shall not exceed 35 ft, unique exceptions, such as agricultural buildings and communication structures may be allowed to exceed <br /> the height limit <br /> ❑ Existing and proposed parking(Commercial/Industrial Only);must show dimensions,width and proposed number of stalls <br /> ❑ Existing and proposed driveway(s); must show dimensions and width *Driveways must have a cleared width of 20 ft and a cleared <br /> height of 13 ft,and sufficient turn-around space for rescue services to utilize <br /> ❑ North arrow <br /> ❑ Vegetation proposed to be removed or disturbed <br /> ❑ Location and extent of proposed filling/grading <br /> ❑ Location and type of erosion control measures <br /> ❑ Construction plans shall be submitted with this application for all items subject to Uniform Dwelling Code(UDC) <br /> inspection. All new dwellings and bunkhouses require UDC inspection. Construction plans shall show interior layout <br /> (including number of bedrooms),exterior profiles and exterior heights. <br /> ❑ Construction plans shall be submitted with this application for all non-dwelling(Commercial/Industrial)related <br /> construction. Construction plans shall show interior layout,exterior profiles and exterior heights. <br /> ❑ Proposed building/structure locations must be staked prior to submitting this application to the Zoning Office. County staff <br /> will do an onsite visit to verify site conditions. If all proposed structures(including decks,patios,retaining walls,etc) are <br /> not staked upon County staff visit,the permit will NOT be issued and it will be returned to the applicant. <br /> ❑ If all existing structures on the parcel are not shown and dimensioned on the plot plan drawing,the permit will NOT be <br /> issued and it will be returned to the applicant. <br /> Page 2 of 3 <br /> Burnett County, WI Land Use Application—Rev 1/2017 <br />