John Andrews <br /> Palmer Lane <br /> i <br /> i <br /> i <br /> Number of Bedrooms 3 Septic Tank Wie er 1000 <br /> Estimated Flow(average)gallons i day 300 Effluent Fitter Polyl k PL-525 <br /> Design Flow(peek),(Estimated x 1.5)gavday 450 Pump Tank Wieser 1000 <br /> Soil Application Rate gal/day/ft 20.7 Pump Type Zo ller 98 <br /> Influent/Effluent Quality Mont hl Average <br /> Fats, Oil &Grease FOG 30 mg/L <br /> Biochemical Oxygen Demand BOD,) 220 mg/L <br /> Total Suspended Solids(TSS) 150 mg/L <br /> IINOTEII= Servicing frequency of 12 months or If ss requires the <br /> Maintenance Schedule Management Plan be recorded with the Register of Deeds. <br /> Service Event Service Frequency <br /> Inspect condition of tank(s) At least once every I 3 Year <br /> Pump out contents of tanks When combined slud a and scum = 1/3 of t nk volume <br /> Inspect dispersal cell(s) At least once every 3 Year <br /> Clean effluent filter At least once every 1 Year <br /> Inspect pump, pump controls&alarm At least once every <br /> Maintenance Instructions <br /> I <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses <br /> or certifications:Master Plumber,Master Plumber Restricted Sewer, POWTS Maintainer, Septage Servicing <br /> Operator. Tank inspection must include a visual inspection of the tank(s)to identify any rr issing or broken <br /> hardware, identify any cracks or leaks, measure the volume of combined sludge and scun i and to check for <br /> any backup or ponding of effluent on the ground surface. The dispersal cell(s)shall be visually inspected to <br /> check the effluent levels in the observation pipes and to check for any ponding of effluent n the ground <br /> surface. The ponding of effluent on the ground surface may indicate a failing condition an J requires the <br /> immediate notification of the local regulatory authority. <br /> i <br /> When the combined accumulation of sludge and scum in any tank equals 1/3 or more of t e tank <br /> volume,the entire contents of the tank shall be removed by a Septage Servicing Operato and <br /> disposed of in accordance with ch. NR 113, Wisconsin Administrative Code. <br /> A service report shall be provided to the Douglas County Zoning Department within 30 days of any <br /> service event. <br /> Start-Up and Operation <br /> For new construction, prior to use of the POWTS check treatment tank(s) for the presenc# of painting <br /> products or other chemicals that may impede the treatment process and /or damage the Pispersal <br /> cell(s). If high concentrations are detected have the contents of the tank removed by a lidensed <br /> Septage Service Operator. <br /> i <br /> System start-up shall not occur when soil conditions are frozen at the infiltrative surface. <br /> Page of <br />