POWTS OWNER'S MANUAL & MANAGEMENT PLAN Page ) of <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner / A6 soA f Septic Tank Capacity „5i at pal 9 NA <br /> Permit a Septic Tank Manufacturer <br /> S/tac� 0 NA <br /> DESIGN PARAMETERS Effluent Filter Manufacturer Po LYZ OK u NA <br /> Number of Bedrooms i G NA Effluent Filter Made! Pi, -sas 1.l NA <br /> i <br /> Number of Public Facility Units ' NA Pump Tank Capacity gal 4 NA <br /> Estimated flow (average) / DO gaitdayPump Tank Manufacturer At NA <br /> Design flow {peak . (Estimated x 1.5 /5V gal?day Pump Manufacturer ANA <br /> Soil Application Rate aiidayft Pump Model Q NA <br /> Standard influent;Effluent Quality E liienthy average' Pretreatment:snit NA <br /> Fats, Oil &Grease (FOG) .. _-;3C mgiL Sand/Gravel Filter 0 Peat Filter <br /> Biochemical Oxygen Demand (BODE) .220 mggrL 0 NA = Mechanical Aeration 0 Wetland <br /> Total Suspended Solids TSS} <_150 mg/L _ �i Disinfection 0: Other: <br /> Pretreated Effluent Quality Monthly average Dispersal Celi(s? 0 NA <br /> Biochemical Oxygen Demand IBOD,i 3D rngiL Kin-Ground (gravity) 0 in-Ground (pressurized) <br /> Total Suspended Solids (TSS) O mgJL A NA 0 At-Grade 9 Mound <br /> Fecal Colifomi it: Genet a mean) _<1Q4 cfu'1OOrnl [ Drip-Line 0 Other: <br /> Maximum Effluent Particle Size a in die. u NA Other: 0 NA <br /> Other: _ NA „s- D NA <br /> ' Cs.trer: <br /> *Values typical for domestic wastewater and septic tali:effi:ar 0 NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Inspect condition of tank(s) ; At least once every: 3 menthls)year(s) (Maximum 3 years) El NA <br /> ,� <br /> Pump out contents of tanks) When combined sludge and scum equals one-turd ?tl of tank volume 0 NA <br /> inspect dispersal cellisi At least once every: earlymon-th si fMaximum 3 rears) 9 NA <br /> � �year(s; <br /> i menInfs <br /> Clean effluent filter At least once every: /3 L: yearis. 0 NA <br /> 1✓ mantaits; <br /> inspect pump, pump controls &alarm At least once every: ;._; yearis; ,121,NA <br /> least ' G =rants) <br /> Flush laterals and pressure test At ast once every: 0 yearly) NA <br /> Other: — mor:thts) DNA <br /> _ <br /> At leas;once every: vearlsj <br /> Other: 0 NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications: <br /> Master Plumber; Master Plumber Restricted Sewer; POWTS Inspector; POWTS Maintainer; Septage Servicing Operator. Tank <br /> inspections must include a visual inspection of the tank(s) to identify any missing or broken hardware, identify any cracks or leaks, <br /> measure the volume of combined sludge and scum and to check for any back up or pending of effluent on the ground surface. <br /> The dispersal cell(s) shall be visually inspected to check the effluent level in the observation pipes and to check for any pending <br /> of effluent on the ground surface. The ponding of effluent on the ground surface may indicate a failing condition and requires the <br /> immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any tank equals one-third 0'13) or more of the tank volume, the entire <br /> contents of the tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113, <br /> Wisconsin Administrative Code. <br /> All other services, including but not limited to the servicing of effluent filters, mechanical or pressurized components, pretreatment <br /> units, and any servicing at intervals of'.12 months, shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 10 days of completion of any service event. <br />