Laserfiche WebLink
End Connection Lateral Layout Vagram <br /> Laterals centered over the A&8 dimension 0=Turn-u p vdbs 11 va lve or of es n outplug l <br /> E P <br /> All laterals are ldentical IEX—>I Hol es drilled on the bottom of the lateral S <br /> equally spaced <br /> Force main connection via tee or cross to manifolds[any polo[. Laterals&force main of PVC Sch 40 <br /> (per COMM Table 84.30-5) <br /> Number of Laterals 2 Orifice Diameter 0.156 in <br /> Lateral Diameter 1.50 in Orifice Spacing ()0 2.55 ft <br /> Lateral Length (P) 48.45 ft Orifices per Lateral 20 <br /> Lateral Spacing (S) 3.00 ft Orifice Density 7.50 ft2/orifice <br /> Lateral Flow Rate 10.77 gpm Manifold Length 3.00 ft <br /> System Flow Rate 21.54 gpm Manifold Diameter 1.50 in <br /> Total Dynamic Head 32.32 ft Forcemain Velocity 2.20 ft/sec <br /> Dose Tank Information Locking cover with waming <br /> label and locking device and <br /> sealed watertight <br /> Electrical as per NEC 300 and —► <br /> Comm 16.28 WAC 4 in.min. <br /> Disconnect <br /> Tank component is properly vented E— Altemate outlet <br /> location <br /> Forcemain diameter <br /> SKAW Manufacturer 2 in. <br /> Ca acit 500.00 Gallons <br /> Volume 14.23 gal/inch A <br /> Weep hole or anti- <br /> Dimension Inches Gallons B siphon device <br /> A 16.68 237.35 C <br /> B 2.00 28.46 P� ump off elevation(n) <br /> C 4.46 63.43 � 73.00 <br /> D 12.00 170.76 D <br /> Total 35.14 500.00 <br /> Dose tank elevation(ft) <br /> 3" Bedding under tank. 72.00 <br /> Alarm Manuafacturer SJE Rhombus <br /> Alarm Model Number ITank Alert <br /> Pump Manufacturer jZoeller <br /> Pump Model Number 1153 <br /> Pump Must Deliver 21.54 gpm at 32.32 ft TDH <br /> Project: Warrick Mound Page 4 of 8 <br />