Laserfiche WebLink
DEPARTMENT OF REPORT ON SOIL BORINGS AND SAFETY & BUILDINGS <br /> INDUSTRY, DIVISION <br /> LABOR AND P.O. BOX 7969 <br /> TINRELATIONS PERCOLATION TESTS (115) MADISON WI 53707 <br /> H , . <br /> yT (I LHR 83.09(1) & Chapter 145) <br /> L ATION: SECTION: TOWNSHIP/MUNICIPALITY: LOTNO.:BLK.NO.: SUBDIVISION NAME: <br /> Y4 1� 24 /T47 N/R 17E I. Swim Town ship 3 CSM V P. 13, Pg. 154 <br /> COUNTY: MAILING ADDRESS: <br /> Buknett Brian Weidendan6 Rt. #i Box 205 Moaa, MN 55051 <br /> USE DATES OBSERVATIONS MADE <br /> NO.BEDRMS.: COMMER IALDESCRIPTION: NS: PERCOLATION ESTS: <br /> 1,1�' Residence 2 ....ES <br /> fNew ❑Replace Sept. 28, 1992 Sept. 28, 1992 <br /> RATING:S=Site suitable for system U=Site umuitable for system <br /> ONVENTIONAL: MOUND: IN-GROUND -IN-FILLHOLDING TANK:RECOMMENDED SYSTEM:(optional) <br /> ®S ❑U ®S ❑U ®S ❑U ❑S DU I El [Al Conventionat <br /> If Percolation Tests are NOT required DESIGN RATE: If any portion of the tested area is in the N/A <br /> under s. ILHR 83.0915)(b),indicate: Floodplain, indicate Floodplain elevation: <br /> PROFILE DESCRIPTIONS <br /> BORING TOTAL DEPTH TO GROUN DWATER-INCHES CHARACTER OF SOIL WITH THICKNESS,COLOR, TEXTURE,AND DEPTH <br /> NUMBER DEPTH IN, ELEVATION OBSERVED EST.HIGHESTTO BEDROCK IF OBSERVED (SEE ABBRV.ON BACK.) <br /> B- 1 None 0-611 Dk Bn ; 6"-61" Bn med. d w1cob; - <br /> 72rr 97.4 61„ Bn compacted 4,s w1cob 8 R mot 446 <br /> 0-611 D Bn e; - n med. h w Co - <br /> B 2 72„ 97.8 None 6711 Bn compacted 6,s w1cob 9 R mat 444 <br /> 0-511 Dk Bn Pis; 511-6511 Bn med. d w/cob; 6511_1211 <br /> g. 3 72” 97'7 None 65r1 Bn compacted �5 w1cob 6 R mot 666 <br /> B- <br /> 4 7211 98 None >72>72" 0-611 Dk Bn t.5; 6"-7211 Bn med. .6 w1cob <br /> B- 5 7211 98.4 None >7211 .same a6 B4 <br /> B- <br /> PERCOLATION TESTS <br /> TEST DEPTH WATER IN HOLE TEST TIME DROP IN WATER LEVEL-INCHES RATE MINUTES <br /> NUMBER INCHES AFTERSWELLING INTERVAL-MIN. PERIOD PERIOD P PER INCH <br /> P. 1 2211 None 5 1 3 4 1 11/16 1 9/16 3 <br /> P- 2 11 one 5 1 11/76 1 9/16 1 1/16 <br /> P- a on 5 1 13/16 1 3/4 1 5/8 <br /> P- <br /> P- <br /> P- <br /> PLOT PLAN: Show locations of percolation tests, soil borings and the dimensions of suitable soil areas. Indicate scale or distances. Describe what are the hori- <br /> zontal and vertical elevation reference points and show their location on the plot plan. Show the surface elevation at all borings and the direction and percent <br /> of land slope. <br /> SYSTEM ELEVATION 95.6 SeaPe 111=401 except where noted. <br /> IBM-106. Benchrank, HRP & URP, NaiP in babe o4 X011 Bcdch <br /> _ _. <br /> 4_ <br /> d Bolting <br /> IT 5 <br /> eP1 <br /> AppaaximatePy 6 AcAea BZ *BM <br /> -j - <br /> ,. <br /> TN <br /> 4 <br /> I <br /> P3 B3 I <br /> I i I <br /> I <br /> - - ------ rA . 690'1 --r $� --- . >3 -------- <br /> I,the undersigned, hereby certify that the soil tests reported on this form were made by me in accord with the procedures and methods specified in the W' consin <br /> Administrative Code,and that the data recorded and the location of the tests are correct to the best of my � <br /> knyojyjwle8e a d belief. ...o..!`'�E� QS• Q / <br /> � �G"tfi"" / <br /> NAME (print): TESTS WERE COMPLETED ON: <br /> Wade Ru6ehotm Septembeh 28, 1992 <br /> ADDRESS: CERTIFICATION NUMBER: P��flON NU�n ER i nal): <br /> 24702 Lind Road P.O. Box 514 Sihen, WI 54872 3583 17 11 .349-7TV <br /> CST SIGNATURE, <br /> DISTRIBUTION: Original and one copy to Local Authority,Property Owner and Soil Tester. <br /> DILHR-SBD-6395(R. 10/83) —OVER — <br />