My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2023/05/30 - SANITARY - SAN - Repl HT - SAN-23-70A
Burnett-County
>
Property Files
>
TOWN OF DANIELS
>
2424
>
2023/05/30 - SANITARY - SAN - Repl HT - SAN-23-70A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/16/2025 11:00:50 AM
Creation date
1/16/2025 10:41:26 AM
Metadata
Fields
Template:
Property Files v2
Document Date
5/30/2023
Document Type 1
SANITARY
Document Type 2
SAN
Document Type 3
Repl HT
County Permit Number
SAN-23-70A
State Permit Number
650952
Tax ID
2424
Pin Number
07-006-2-38-17-21-5 05-003-016000
Legacy Pin
006242101210
Municipality
TOWN OF DANIELS
Owner Name
RON P JOHNSON KATHLEEN LARRABEE
Property Address
23566 OLD 35
City
SIREN
State
WI
Zip
54872
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
HOLDING TANK SPECIFICATIONS <br /> 3 INumber of bedrooms <br /> Non-residential estimated flow(gpd) <br /> 2000.0 JMinimum holding tank volume required (gal) <br /> 3000.0 JProposed holding tank capacity(gal) <br /> Wieser Concrete Tank Manufacturer <br /> WLP3000 Tank model number <br /> SJE Rhombus Alarm manufacturer <br /> Tank Alert 1 Alarm model number <br /> Tank Dimensions and Data Tank Anchor Calculations <br /> X for round tank 25280 Ibs Weight of tank and cover <br /> 43.0 Liquid depth below inlet invert(in) 1.25 Safety factor <br /> 8.0 Maximum depth of soil cover(ft) 27880 Ibs Weight of anchor required <br /> 62.8 Height(in) Outside 25.7 in Soil cover req. for anchor or <br /> 184.0 Length (in) Dimensions 1 6.9 lyd3 Concrete counter weight <br /> 102.0 Width (in) I Only <br /> HOLDING TANK CROSS SECTION <br /> manhole cover with <br /> locking device and finished vent cap <br /> junction warning label grade <br /> box —� <br /> < —23 in. <br /> 4"min. 12"min. <br /> Manhole and vent locations <br /> conduit —� vent pipe <br /> 18"min. <br /> tether weight - <br /> building sewer <br /> 12.0 In. <br /> service � — —•----- —.— ------ <br /> inlet <br /> blind plug alarm on Note: All tank joints, and <br /> to seal joints between tank <br /> outlet openings and piping are <br /> Electrical as per 31.0 in. sealed watertight. All <br /> NEC 300 pipe and vent materials <br /> and SPS 316 comply with SPS 384. <br /> 3 in.bedding under tank. Tank is anchored as necessary to negate buoyancy. <br /> Project: Johnson Holding Tank Installation <br /> Transaction Number: Page 2 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.