Laserfiche WebLink
Do not drive or park vehicles over tanks and dispersal cells. <br /> Reduction or elimination of the following from the wastewater stream may improve the performance and prolong <br /> the life of the POWTS: antibiotics, baby wipes, cigarette butts, condoms, cotton swabs, degreasers, dental <br /> floss, diapers, disinfectants, fat, foundation drain (sump pump)water, gasoline, grease, oil, painting products, <br /> pesticides, sanitary napkins, tampons, and water softener brine. <br /> Abandonment <br /> When the POWTS fails and/or is permanently taken out of service the following steps shall be taken to insure <br /> that the system is properly and safely abandoned in compliance with Wisconsin Administrative Code SPS <br /> 383.33-1 <br /> -All piping to tanks and pits shall be disconnected and the abandoned pipe openings sealed. <br /> -The contents of all tanks and pits shall be removed and properly disposed of by a Septage Servicing Operator. <br /> -After pumping, all tanks and pits shall be excavated and removed or their covers removed and the voidspace <br /> filled with soil, gravel or another inert solid material. <br /> Continsaency Plan <br /> If the POWTS fails and cannot be repaired the following measurers have been, or must be taken to provide a <br /> code compliant replacement system: (Check One) <br /> The site has not been evaluated to identify a suitable replacement area. Upon failure of the POWTS a soil <br /> and site evaluation shall be performed to locate a suitable replacement area. If no replacement area is available <br /> a holding tank may be installed to replace the failed POWTS. <br /> EIA suitable replacement area has been evaluated and may be utilized for the location of a replacement soil <br /> absorption system. The replacement area should be protected from disturbance and compaction and should no <br /> be infringed upon by required setbacks from existing and proposed structures, lot lines and wells. Failure to <br /> protect the replacements area will result in the need for a new soil and site evaluation to establish a suitable <br /> replacement area. Replacement systems must comply with the rules in effect at that time. <br /> ❑ A suitable replacement area is not available due to setback and/or soil limitations. A holding tank may be <br /> installed to replace the failed POWTS. <br /> IIWARNINGII <br /> Septic, pump and other treatment tanks may contain lethal gasses and/or insufficient oxygen. Do not enter a <br /> septic, pump or other treatment tank under any circumstances. Death may result. Rescue of a person from the <br /> interior of a tank may be difficult or impossible. <br /> POWTS Installer Septic Pumper <br /> Name IJackson Plumbing Name <br /> Phone# 715-566-2786 jPhone# <br /> POWTS Maintainer Local Regulatory Authority <br /> Name I Agency I Burnett County Zoning <br /> Phone# I jPhone# 715-349-2138 <br /> 7 of 7 <br />