Laserfiche WebLink
In Ground System Maintenance and Operation Specifications <br /> Service Provider's Name GRANTSBURG SANITATION Phone 715-488-2284 <br /> POWTS Regulator's Name BURNETT COUNTY ZONING Phone 715-349-2109 <br /> System Flow and Load Parameters <br /> Design Flow-Peak 300 gpd Maximum Influent Particle Size 1/8 in <br /> Estimated Flow-Average 200 gpd Maximum BOD5 30 mg/L <br /> Septic Tank Capacity 840 gal Maximum TSS 30 mg/L <br /> Soil Absorption Component Size 162.5 ft2 Maximum FOG 10 mg/L <br /> Type of Wastewater Domestic Maximum Fecal Coliform 10E4 cfu/100 mL <br /> Service Frequency <br /> Septic and Pump Tank Inspect and/or service once every 3 years <br /> Effluent Filter Inspect and clean as necessary at least once every 3 years <br /> Pump and Controls Test once every 3 years <br /> Alarm Should test periodical) <br /> Pressure System Laterals should be flushed and pressure tested every 3 years <br /> In Ground I Inspect for ponding and seepage once every 3 years <br /> Miscellaneous Construction and Materials Standards <br /> 1. Observation pipes are slotted and materials conform to Table SPS 384.30-1, have a watertight cap <br /> and are secured in as shown in the GeoMat In Ground Component Manual Ver. March 20, 2017. <br /> 2. Dispersal cell media conforms to GeoMat products approved for use with the GeoMat In Ground Component <br /> Manual Ver. March 20, 2017. Media is covered with an approved geotextile fabric. <br /> 3. All gravity and pressure piping materials conform to the requirements in SIPS 384,Wis.Adm. Code. <br /> 4. Scarification of basal area is accomplished with a rake or other tool. <br /> 5. All disturbed areas will be seeded and mulched to prevent soil erosion and help reduce frost penetration. <br /> Rearm*nd ap <br /> Vent Cape _ <br /> 12"Min <br /> __L _____-__ <br /> I <br /> Dist Laterals — <br /> -- _ - - <br /> 12"113TM C 33 S <br /> System elevation <br /> 96.5 Feet <br /> Project: PEGGY LEWIS Page 6 of 13 <br />