My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015/06/30 - SANITARY - SAN - Other
Burnett-County
>
Property Files
>
MULTI PARCEL DOCS
>
Other
>
2015/06/30 - SANITARY - SAN - Other
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2025 8:55:06 AM
Creation date
9/27/2017 10:11:58 PM
Metadata
Fields
Template:
Property Files v2
Document Date
6/30/2015
Document Type 1
SANITARY
Document Type 2
SAN
Document Type 3
Other
County Permit Number
SAN-15-92
Tax ID
36067
Pin Number
07-036-2-40-17-14-3 02-000-011001
Municipality
TOWN OF UNION
Owner Name
WILSON TRUST
Property Address
28562 PARDUN RD
City
DANBURY
State
WI
Zip
54830
Previous Owners
JEROME J WILSON MARY J WILSON SIMEON J WILSON JAMIN J WILSON
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
POWTS OWNER'S MANUAL & MANAGEMENT PLAN Pagel ofd <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner JEROME& BONNIE WILSON Tank Manufacturer Wieser Concrete ❑ NA <br /> Permit# IN <br /> Septic [I Dose [I Holding vol. 1000 gal <br /> DESIGN PARAMETERS Tank Manufacturer 50 NA <br /> Number of Bedrooms 3 ❑ NA ❑Septic ❑ Dose ❑ Holding vol. gal <br /> Number of Public Facility Units NA Vertical Distance Tank Bottom(s)to Service Pad: ft. <br /> Estimated (average)flow 300 gal/day Horizontal Distance Tank(s)to Service Pad: ft. <br /> Design(peak)flow=(Estimated x 1.5) 450 gal/day Speck servicing mechanics must be provided if vertical is>15 ft.or <br /> Soil Application Rate if horizontal is>150 ft. Specific instructions to be provided on back. <br /> al/da /ft2 <br /> Standard Influent/Effluent Quality Monthly average Effluent Filter Manufacturer Tuf-Tate ❑ NA <br /> Fats, Oil&Grease (FOG) <30 mg/L Effluent Filter Model EF-6 <br /> Biochemical Oxygen Demand (BODS) x220 mg/L ❑ NA Pump Manufacturer WSJ NA <br /> Total Suspended Solids (TSS) <150 mg/L Pump Model <br /> High Strength Influent/Effluent Monthly average' Pretreatment Unit <br /> Fats, Oil&Grease (FOG) <30 mg/L Manufacturer ® NA <br /> Biochemical Oxygen Demand (BODS) <220 mg/L fjd NA ❑Mechanical Aeration ❑ Peat Filter <br /> Total Suspended Solids (TSS) <150 mg/L ❑ Disinfection ❑Wetland <br /> Pretreated Effluent Quality Monthly average ❑ Sand/Gravel Filter ❑ Other: <br /> Biochemical Oxygen Demand (BODS) s30 mg/L Soil Absorption System ❑ NA <br /> Total Suspended Solids (TSS) <30 mg/L NA [jj In-Ground(gravity) ❑ In-Ground(pressurized) <br /> Fecal Coliform (geometric mean) <104 cfu/100m1 ❑At-Grade ❑ Mound <br /> Maximum Effluent Particle Size k in dia. ❑ NA ❑ Drip-Line ❑ Other: <br /> Other: ❑ NA Other: ❑ NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Inspect condition of tank(s) At least once every: 3 ❑®m0ear sar(s) ) (Maximum 3 years) [INA <br /> Pump out contents of tank(s) ®When combined sludge and scum equals one-third('h)of tank volume ❑ NA <br /> ❑When the high water alarm is activated <br /> month <br /> Inspect dispersal cell(s) At least once every: 3 ❑year(s)(s) (Maximum 3 years) ❑ NA <br /> Clean effluent filter At least once every: 3 ❑years) or as needed month(s) ❑ NA <br /> Inspect pump, pump controls&alarm At least once every: ❑month(s) ❑ NA <br /> ❑year(s) <br /> Flush laterals and pressure test At least once every: ❑month(yeaarr((ss)) ) C1 NA <br /> ❑ <br /> Other: At least once every: El m yeaarr((ss)) ) [INA <br /> ❑ <br /> Other: <br /> ❑ NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications: Master Plumber; Master <br /> Plumber Restricted Sewer; POWiS Inspector; POWTS Maintainer; Septage Servicing Operator (pumper). Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and a <br /> check for any back up or ponding of effluent on the ground surface. The dispersal cell(s)shall be visually inspected to check the effluent levels in the <br /> observation pipes and to check for any ponding of effluent on the ground surface. The ponding of effluent on the ground surface may indicate a failing <br /> condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third (Y)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> All other services,including but not limited to the servicing of effluent filters,mechanical or pressurized components,pretreatment units,and any servicing <br /> at intervals of<12 months,shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 30 days of completion of any service event. (rev. 12/12) <br />
The URL can be used to link to this page
Your browser does not support the video tag.