Laserfiche WebLink
HOLDING TANK SPECIFICATIONS <br /> 2 Number of bedrooms <br /> Non-residential estimated flow(gpd) <br /> 2000.0 Minimum holding tank volume required (gal) <br /> r--30-0-0-0-1 Proposed holding tank capacity(gal) <br /> Skaw Tank Manufacturer <br /> Low Profile 3600 Tank model number <br /> S &J Electro ]EIAlarm manufacturer <br /> 101-01H Alarm model number <br /> Tank Dimensions and Data Tank Anchor Calculations <br /> X for round tank 17930 lbs Weight of tank and cover <br /> 56.0 Liquid depth below inlet invert (in) 1.25 Safety factor <br /> 6.0 Maximum depth of soil cover(ft) 22557 lbs Weight of anchor required <br /> 66.0 Height (in) Outside . 25.0 in Soil cover req. for anchor or <br /> 180.0 Length (in) Dimensions 5.8 yd' Concrete counterweight <br /> 75.5 Width(in) I Only <br /> HOLDING TANK CROSS SECTION <br /> manhole cover with <br /> locking device and finished vent cap <br /> junctioW <br /> warning label <br /> grade <br /> 4"min. .lr 12'min. <br /> Manhole and vent locationsmay n reversed. "antpipe18"min.12.0 in '—'—'--------'—'----,—'— building sewer <br /> plug alarm on Note: All tank joints, and inlet <br /> blind <br /> to seal joints between tank <br /> outlet openings and piping are <br /> Electrical as per 44.0 in. sealed watertight. All <br /> NEC 300 pipe and vent materials <br /> and Comm 16 comply with Comm 84. <br /> 3 in.bedding under tank. Tank is anchored as necessary to negate buoyancy. <br /> Project: Lehn Holding Tank <br /> Transaction Number: N/A Page 2 of 4 <br />