My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2025/05/01 - SANITARY - SAN - Repl Non-Press - SAN-25-42
Burnett-County
>
Property Files
>
TOWN OF OAKLAND
>
14670
>
2025/05/01 - SANITARY - SAN - Repl Non-Press - SAN-25-42
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/15/2025 12:00:21 PM
Creation date
10/15/2025 11:49:28 AM
Metadata
Fields
Template:
Property Files v2
Document Date
5/1/2025
Document Type 1
SANITARY
Document Type 2
SAN
Document Type 3
Repl Non-Press
County Permit Number
SAN-25-42
State Permit Number
662188
Tax ID
14670
Pin Number
07-020-2-40-16-19-5 15-360-081000
Legacy Pin
020920011600
Municipality
TOWN OF OAKLAND
Owner Name
JON & ANN DIETMAN
Property Address
8071 PARK ST
City
DANBURY
State
WI
Zip
54830
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PAGE 4OF4 <br /> In-ground Gravity Management Plan <br /> C R'A 7= <br /> ...;w-t;vnner of this in-ground gravity system shall be responsible for its perpetual operation and maintenance pursuant to <br /> mquirements of SPS 382-384,Wisc.Admin. Code. Pursuant to SPS 383.52(2),Wisc.Admin.Code,this system shall <br /> be considered a human health hazard if not maintained in accordance with this approved management plan. <br /> Furthermore, all inspection and maintenance activities shall be performed by a registered POWTS Maintainer in <br /> accordance with SPS 383.52(3),Wisc.Admin. Code. <br /> h iaximurn Dispersal Area Operating Limits: <br /> °ssegn Ficy,�s® y�6> gpd; BODS<_220 mgL"'; TSS <_ 150 mgL''; FOG <_30 mgL-' <br /> .isgection Checklist INSPECT EVERY 3 YEARS <br /> • type of use <br /> o age of systei^ <br /> • nuisance factors(i.e. odors, user complaints, etc.) <br /> • mechanical malfunction (i.e., pumps,valves, switches,floats, etc.) <br /> • material fatigue(i.e., leaks, breaks, corrosion, etc.) <br /> a solids volume in anaerobic treatment tank(s)and any distribution appurtenance(s) (i.e.,distribution/drop boxes) <br /> o neglect or improper use(i.e., exceeding design capacities, prohibited activities, etc.) <br /> c extent of ponding in distribution cell prior to dosing <br /> o dosing irregularities-if applicable(i.e., pump re-cycling,float switch settings, etc.) <br /> o electrical components-if applicable(Le.,wiring, connections, switches, controls,timers, alarms, etc.) <br /> • distribution lateral or lateral orifice plugging (measure lateral distal pressure—compare to design specification) <br /> o surface discharge of effluent or sewage back-up into structure served <br /> iait>tenance Checklist MAINTAIN EVERY 3 YEARS (or when necessary) <br /> o Septic and dose tank(s)shall be pumped by a certified septage servicing operator licensed under s. 281.48 Wis. <br /> Stats.when the volume of solids in the tank(s)exceeds one-third (113)the liquid volume of the tank(s)or <br /> as required by local ordinance. Disposal of contents shall be pursuant to NR 113,Wisc.Admin.Code. <br /> c E_ff cent Enter(§)shall be inspected every 3 years and shall be cleaned when necessary to remove any <br /> accumulated solids according to manufacturer's specifications. A servicing period will always be greater than 12 <br /> Months. <br /> SysteU: maintenance reports shall be submitted to the proper local government unit in accordance with <br /> SPS 383.55 Wisc.Admin. Code. Report any component failure or malfunction to: <br /> s« e of i �dividual or company:�A d� �u�s��/� Phone: 3 yy -7--rZ <br /> .cca v.o ernmen is unit: ,,e >--1-47' Phone: <br /> _oca ro er"3 sent unit address: ZIP: g 72_ <br /> Any defective part of this system shall be repaired, replaced, or removed pursuant to SPS 383.51 (1),Wisc.Admin. <br /> Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383,Wisc.Admin.Code. <br /> \Ic product for chemical or physical restoration of the POWTS may be used unless approved by the department in <br /> accordance with SPS 384,Wisc.Admin. Code. <br /> :r t~e evert that any failed treatment component of this POWTS cannot be repaired, it shall be replaced pursuant to <br /> a plan submitted to the appropriate agency for review and approval. A failed in-ground dispersal component may be <br /> abandoned and replaced by a code-complying dispersal component in a pre-determined area of suitable soils. <br /> 6�r��.r.—n Abandscnment <br /> ,use of 41 i POWTS is discontinued, it shall be abandoned in accordance with SPS 383.33,Wisc.Admin.Code. <br />
The URL can be used to link to this page
Your browser does not support the video tag.