Laserfiche WebLink
Lateral Layout Diagram <br /> Force main oomection via tee or cross to manifold at any point. Laterals are identical <br /> IE P S <br /> L <br /> •-Turo-up Wball wive or IE X�IE tr2 tr2� Laterals&face main of PVC Sch 40 <br /> cleanoutplug per COMMA Table 84.30-5 <br /> Holes drilled on the bottom of the lateral. <br /> Number of Laterals 4 Orifice Diameter 0.125 in <br /> Lateral Diameter 1.50 in Orifice Spacing (X) 1.93 ft <br /> Lateral Length (P) 49.22 ft Orifices per Lateral 26 <br /> Lateral Spacing (S) 3.00 ft Orifice Density 5.77 ft2/orifice <br /> Lateral Flow Rate 10.71 gpm Manifold Length 3.00 ft <br /> System Flow Rate 42.84 gpm _ Manifold Diameter 2.00 in <br /> Total Dynamic Head 22.29 ft Forcemain Velocity 4.38 ft/sec <br /> Dose Tank Information Locking cover with warning <br /> label and locking device and <br /> sealed watertight <br /> Electrical a5 per NEC 300 and —► -} <br /> Comm 16.28 WAC l 4 in.min. <br /> Disconnect — <br /> Tank component is properly vented Aftemate outlet <br /> location <br /> Forcemain diameter <br /> Huffcutt Manufacturer �_ 2 in. <br /> Ca acit 768.00 Gallons <br /> Volume 17.00 gal/inch A <br /> Weep hole or anti- <br /> Dimension Inches Gallons B siphon device <br /> A L 49'19 496.27 C <br /> B 2.00 34.00 Pump off elevation(ft) <br /> C 101.73 82.67 <br /> D 8.00 136.00 D <br /> Total 45. 768.00 <br /> Dose tank elevation ft) <br /> 82.00 <br /> Alarm Manuafacturer IS J Electrol <br /> Alarm Model Number I 101 H W <br /> Pump Manufacturer lZoeller <br /> Pump Model Number 1163 <br /> Pump Must Deliver 42.84 gpm at —22.-2-91 ft T D H <br /> Project: New 4 Bedroom Home Page 4 ofv <br />