Laserfiche WebLink
HOLDING TANK SPECIFICATIONS <br /> 3 Number of bedrooms <br /> Non-residential estimated flow(gpd) <br /> 2000.0 Minimum holding tank volume required (gal) <br /> 3000.0 Proposed holding tank capeci (gal) <br /> Wieser Concrete Tank Manufacturer <br /> W3000-MR Tank model number <br /> S.J.Electro Alarm manufacturer <br /> 101-01H Alarm model number <br /> Tank Dimensions and Data Tank Anchor Calculations <br /> X for round tank 19540 lbs Weight of tank and cover <br /> 51.0 Liquid depth below inlet invert(in) 1.50 Safety factor <br /> 8.0 Maximum de th of soil cover(ft) 46985 lbs Weight of anchor required <br /> 71.0 Height(in) Outside 40.9 in Soil cover req. for anchor or <br /> 186.0 Length(in) Dimensions 11.6 yd Concrete counter weight <br /> 93.0 Width(in) Only <br /> HOLDING TANK CROSS SECTION <br /> manhole cover with <br /> �— locking device and finished vent cap <br /> junction warning label grade <br /> box <br /> 4"min. 12"min. <br /> 24 in. <br /> Manhole and vent locations <br /> conduitvent pipe <br /> may be reversed. 1E"min. <br /> building sewer <br /> ---- service � 12.0 in. --------•—•—•—•—•---•--- inlet <br /> blind plug alarm on Note: All tank joints, and <br /> to seal joints between tank <br /> outlet openings and piping are <br /> Electrical as per 39.0 in. sealed watertight. All pipe <br /> NEC 300 and vent materials comply <br /> and Comm 16 with Comm 84. <br /> 3 in.bedding under tank. Tank is anchored as necessary to negate buoyancy. <br /> Project: David and Marilyn Almlie Holding Tank <br /> Transaction Number-, Page 2 of 4 <br />