Laserfiche WebLink
POWTS OWNER'S MANUAL MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner lZ M AOWSTEK, Septic Tank Capacity 400 gal ❑NA <br /> Permit# oj/ Septic Tank Manufacturer rpkWy CO/&M ❑NA <br /> DESIGN PARAMETERS Effluent Filter Manufacturer XABLF_ ❑NA <br /> Number of Bedrooms I00gpd/bedroom Z-00 ❑NA Effluent Filter Model A t oo ON ❑NA <br /> Number of Commercial Units NA Pump Tank Capacity gal 1$(NA <br /> Estimated flow(average)* 300 gal/day Pump Tank Manufacturer ff NA <br /> Design flow(peak),estimated x 1.5* gal/day Pump Manufacturer Vf NA <br /> Pwnp Model NA <br /> Soil,Application Rate 0,lo gal/day Pretreatment Unit R1,NA <br /> Influent/Effluent Quality(NAIM) Monthly Average** ❑ Sand/Gravel Filter ❑ Peat Filter <br /> Fats.Oil&Grease(FOG) < 30 mg/L ❑ Mechanical Aeration ❑ Wetland <br /> Biochemical Oxygen Demand(BODs) 220 mg/L ❑Disinfection ❑ Other: <br /> Total Suspended Solids(TSS) Manufacturer: Model: <br /> :5; mg/L Dispersal Cell(s) <br /> Pretreated Effluent Quality ❑ Monthly Average*** )WIn-ground(gravity) ❑ In-ground(pressurized) <br /> Biochemical Oxygen Demand(BODS) < 30 mg/L ❑At-grade ❑Mound <br /> Total Suspended Solids(TSS) < 30 mg/L ❑ Drip-line ❑ Other: <br /> Fecal Coliform(geometric mean) <10+cfu/100ml ❑ Leaching Chamber Manufacturer tv '/{of a!- <br /> Maximum Effluent Particle Size 1/8 inch diameter Model ' Approval Stipulation <br /> *Wastewater Flow Verification on and calculations: Soil Application Rate�gpd/ft2 Area Req. $ 0 D <br /> (Other than bedroom based) Absorption Area Credit per unit 3 1, 1 ft2 <br /> Minimum Number of Chambers l 7 <br /> ❑Aggregate Design Flow/Loading Rate= min <br /> ** Values typical for domestic(non-commercial wastewater Materials:all materials must comply with WI Adm.Code <br /> and septic tank effluent. COMM84 and be installed per manufacturers specifications <br /> ***Values typical for pretreated wastewater. and approval letters. <br /> DESIGN CRITERIA <br /> ❑"Wisconsin At-grade Soil Absorption System,Siting,Design&Construction Manual"(Converse et.al.1990) <br /> ❑"Wisconsin Mound Soil Absorption System:Siting,Design&Construction Manual"Converse,J.C_and E.J.Tyler. <br /> Publication 15.22 <br /> ❑"Design of Pressure Distribution Networks for Septic Tank-Soil Absorption Systems"Publications 9.6 <br /> "Design of Conventional Soil Absorption Trenches and Beds". R.J.Otis—ASAE Publications 5-77 and"Design Manual— <br /> Onsite Wastewater Treatment and Disposal Systems".EPA 625/1-80-012 October 1980 <br /> ❑ SBD—10570—P(R.6/99)"At-Grade Component Manual Using Pressure Distribution" <br /> ❑ SBD— 10567—P(8.6/99)"In Ground Absorption Component Manual" <br /> �(SBD— 10705—P(N.01/01)"In Ground Soil Absorption Component Manual"Version 2.0 <br /> ❑ SBD—10628—P(N.6/99)"Recirculating Sand Filter System Component Manual" <br /> ❑ SBD— 10656—P(N.6/99)"Split Bed Recirculating Sand Filter System Component Manual" <br /> ❑ SBD - 10572—P(8.6/99)"Mound Component Manual" <br /> ❑ SBD - 10691—P(N.01/01)"Mound Component Manual"Version 2.0 <br /> ❑ SBD - 10595—P(R.6/99)"Single Pass Sand Filter Component Manual" <br /> ❑ SBD - 10657—P(86/99)"Drip-line Effluent Disposal Component Manual" <br /> ❑ SBD - 10573—P(R 6/99)"Pressure Distribution Component Manual" <br /> ❑ SBD - 10706—P(N.01/01)"Pressure Distribution Component Manual"Version 2.0 <br /> ❑ Drip-line Effluent Dispersal Component Manual for Multi-flo Onsite Wastewater Treatment Units <br /> 13 <br /> MAINTENANCE AND MANAGEMENT <br /> MAINTENANCE MONITORING SCHEDULE <br /> Service Event Service Frequency <br /> Inspect condition of tank(s) At least once every ❑months ®year(s) (Maximum 3 yrs.) <br /> Pump out contents of tank(s) When combined sludge and scum equals one-third(1/3)of tank volume <br /> Inspect dispersal cell(s) At least once every ❑ months ®year(s) (Maximum 3 yrs.) <br /> Clean effluent filter At least once every ❑months 0 year(s) <br /> Inspect pump,pump controls&alarm At least once every ❑months ❑year(s) IN NA <br /> Flush laterals and pressure test At least once every ❑months ❑year(s) 91 NA <br /> Valves At least once every ❑months ❑year(s) ® NA <br /> Other: At least once every ❑months ❑year(s) ® NA <br /> Page__Z_of 5-- <br />