HOLDING TANK SPECIFICATIONS <br /> Number of bedrooms <br /> Non-residential estimated flow(gpd) <br /> 2000.0 Minimum holding tank volume required (gal) <br /> 2500.0 Proposed holding tank capacity(gal) <br /> Wieser Concrete JTank Manufacturer <br /> WLP25000 Tank model number <br /> SJE Rhombus JAlarm manufacturer <br /> Tank Alert JAlarrn model number <br /> Tank Dimensions and Data Tank Anchor Calculations <br /> X for round tank 26110 lbs Weight of tank and cover <br /> 36.0 Liquid depth below inlet invert(in) 1.50 Safety factor <br /> 8.0 Maximum de th of soil cover(ft) 30872 lbs Weight of anchor required <br /> 56.8 Height(in) Outside 25.1 in Soil cover req. for anchor or <br /> 183.2 Length (in) Dimensions 7.6 yd' Concrete counterweight <br /> 101.2 Width (in) Only <br /> HOLDING TANK CROSS SECTION <br /> manhole:cover with <br /> locking device and finished vent cap <br /> Tconduft <br /> warning label grade <br /> 4"min. 12"min. <br /> Manhole and vent locations <br /> vent pipe18"min. <br /> 12.0 in. — — _ __ _ _ building sewer <br /> inlet <br /> blind plug alar,on Note: All tank joints, and <br /> to seal joints between tank <br /> outlet openings and piping are <br /> Electrical as per 24.0 in. sealed watertight. All <br /> NEC 300 pipe and vent materials <br /> and Comm 16 comply with Comm 84. <br /> 3 in.bedding under tank. Tank is anchored as necessary to negate buoyancy. <br /> Project: Blossum Management and Development Company <br /> Transaction Number: Page 2 of 7 <br />