Laserfiche WebLink
POWTS OWNER'S MANUAL & MANAGEMENT PLAN Page 1 of__ <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner JEFFREY P&ROBIN J SVENTEK Tank Manufacturer Wieser Concrete ❑NA <br /> Permit# <br /> IN Septic El Dose ❑ Holding vol. 1600 gal <br /> DESIGN PARAMETERS Tank Manufacturer ❑NA <br /> Number of Bedrooms 5 ❑NA ❑ Septic [RDose ❑ Holding vol. 1000 gal <br /> Number of Public Facility Units NA Vertical Distance Tank Bottom(s)to Service Pad: ft. <br /> Estimated(average)How 500 gal/day Horizontal Distance Tank(s)to Service Pad: ft. <br /> Design(peak)flow=(Estimated x 1.5) 750 gal/day Specific servicing mechanics must be provided if vertical is>15 ft.or <br /> Soil Application Rate 1.0 al/da /f? if horizontal is>150 ft. Specific instructions to be provided on back. <br /> Standard Influent/Effluent Quality Monthly average Effluent Filter Manufacturer Tuf-Tlte ❑NA <br /> Fats, Oil&Grease (FOG) <30 mg/L Effluent Filter Model EF-6 <br /> Biochemical Oxygen Demand (BOD5) <_220 mg/L ❑NA Pump Manufacturer Zoeller ❑NA <br /> Total Suspended Solids (TSS) <150 mg/L Pump Model 152 <br /> High Strength Influent/Effluent Monthly average' Pretreatment Unit <br /> Fats, Oil&Grease (FOG) s30 mg/L Manufacturer ®NA <br /> Biochemical Oxygen Demand (BODS) <_220 mg/L NA ❑Mechanical Aeration ❑ Peat Filter <br /> Total Suspended Solids (TSS) <150 mg/L ❑Disinfection ❑Wetland <br /> Pretreated Effluent Quality Monthly average ❑Sand/Gravel Filter ❑ Other: <br /> Biochemical Oxygen Demand (BOD5) <30 mg/L Soil Absorption System ❑NA <br /> Total Suspended Solids (TSS) <30 mg/L f7 NA ❑ In-Ground(gravity) ❑ In-Ground(pressurized) <br /> Fecal Coliform (geometric mean) <10"cfu/100ml ❑At-Grade 00 Mound <br /> Maximum Effluent Particle Size Ya in dia. ❑NA ❑ Drip-Line ❑ Other: <br /> Other: ❑NA Other: ❑NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Inspect condition of tank( ) every: 3 s At least once eve ❑®year(s)ar(s) ) <br /> (Maximum 3 years) ❑ NA <br /> Pump out contents of tank(s) ®When combined sludge and scum equals one-third(36)of tank volume ❑NA <br /> ❑When the high water alarm is activated <br /> month <br /> Inspect dispersal cell(s) At least once every: 3 ❑y ar(s)(s) (Maximum 3 years) ❑NA <br /> Clean effluent filter At least once every 3 ❑year(s) ) <br /> ar(s) ) or as needed ❑ <br /> ffl NA <br /> Inspect pump, pump controls&alarm At least once every: ❑ month(s) ❑NA <br /> 3 year(s) or as needed <br /> Flush laterals and pressure test ❑month(s) ❑NA At least once every: <br /> ❑year(s) as needed <br /> Other: [I month(s) NA <br /> At least once every: ❑year(s) ❑ <br /> Other: <br /> ❑NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications: Master Plumber; Master <br /> Plumber Restricted Sewer; POWTS Inspector; POWTS Maintainer; Septage Servicing Operator (pumper). Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and a <br /> check for any back up or ponding of effluent on the ground surface. The dispersal cell(s)shall be visually inspected to check the effluent levels in the <br /> observation pipes and to check for any ponding of effluent on the ground surface. The ponding of effluent on the ground surface may indicate a failing <br /> condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(%)or more of the tank volume, the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> All other services,including but not limited to the servicing of effluent filters,mechanical or pressurized components,pretreatment units,and arty servicing <br /> at intervals of<12 months,shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 30 days of completion of any service event. (rev. 12112) <br />