Laserfiche WebLink
Jeffrey &.Robin Sventek Page 4 of 6 <br /> Pipe Lateral Layout and <br /> Detail of Lift Pump Tank <br /> Laterals centered over the A dimension ♦-Turn-up wfball valve or cleanoutplu0 <br /> rForce <br /> _-- Pl laterals are identical 14-X--3I Holes drilled on the bottom of the lateralequally spaced <br /> main connection Via tee or cross to manifold at any point. Laterals&force main of PVC Sch 40 <br /> (per.a Table 84.30-5) <br /> Number of Laterals 4 Hole Diameter 3/16 Inch <br /> Lateral Length P = 44 Ft. p Lateral Diameter 1.50 Inches <br /> Manifold Length R = 11�!�rF^t 11" X = 35.20 In. Manifold Diameter 2.00 Inches <br /> Pipe Spacing S = Ft. Y = 35.20 In. # of Holes per Pipe 16 <br /> ,b <br /> Holes at in Inches 0.0 35.2 70.4 105.6 140.8 176.0 211.2 246.4 281.6 Etc. <br /> Tank Manufacturer: Wieser Concrete Products Inc. Size: 1000 Gallons <br /> Liquid Depth: 36 Inches or 27.8 Gallons Per Inch <br /> Internal Dimensions of Pump Chamber Width 80 Inches Length 80.2 Inches <br /> Minimum Distribution Rate: 64 Holes X .66 = 42.24 Gallons Per Minute <br /> Force Main Diameter 2.00 Inches Each Dose 141.8 Gallons <br /> Length of Force Main 50.00 Ft. Drain Back 8.2 Gallons <br /> System Elevation 99.25 Ft. Total Dose Volume 150.0 Gallons <br /> Lateral Invert Elevation 99.75 Ft. <br /> Pump Off Elevation 91.00 Ft. Capacities <br /> Vertical Difference 8.75 Ft. A 24.6 Inches or 684 Gallons <br /> Minimum Pressure 3.25 Ft. B 2.0 Inches or 56 Gallons <br /> Hazen-Williams .Friction Loss 1.83 Ft. C 5.4 Inches or 150 Gallons <br /> D 4.0 Inches or 111 Gallons <br /> Total Dynamic Head 13.83 Ft. Total 36.0 Inches or 1001 Gallons <br /> PUMP <br /> Manufacturer: Zoeller <br /> Model Number: 152 <br /> Switch Type: Mechanical <br /> Alarm <br /> Manufacturer: S. J. Electro PUMP CHAMBER OR COMBINATION PUMP CHAMBER CROSS SECTION <br /> Systems, Inc. 4" PVC 3' min. NOTE: pump & alarm to lockingse I. ail joints to p voter type <br /> y 9 be installed on separate circuits union devic con ult and of an approved type <br /> onto solid round <br /> Model Number: Tank Alert 1 min. 18" below grade approved optional (typ) opt ons location <br /> Switch Type: Mechanical from septic tank or "WARNING" label for clever <br /> YP opening from septic 4" approved vent weatherproof <br /> comportment of A ��min. 12" above grade �1 electrical <br /> combination tonkN it n e n e a g r a c e - - - receptacle <br /> i \ 24" I.D. manhole <br /> 4" X 2" femco <br /> 2927965 i '" , y to alarm to seal end <br /> inlet fuel to power source/ <br /> A <br /> �- alarm <br /> 8 <br /> Pump Off Elevation 91. A Ft-� k,� ,.�e a + an- 2" schd 40 <br /> sl Tw ulryurN"R unw.- <br /> P.,w p°nIP force main <br /> u Ciiwtan septic IwM1/ c xwbe. (` <br /> In.e conlyumllon of maYwk w v"nb <br /> m.y an.r mP.,ayy oe m.meeere�lw.r 4" Ws id min. <br /> 1 pYRv' °H- onto solid ground <br /> 1/4" weep hole <br /> D pump <br /> simplex or <br /> .. „ duplex pump and <br /> "3 approved beddina� _"_ alarm controls (typ) <br />