HOLDING TANK SPECIFICATIONS <br /> 4 Number of bedrooms <br /> Non-residential estimated flow(gpd) <br /> 2000.0 Minimum holding tank volume required (gal) <br /> 2000.0 Proposed holding tank capacity(gaq <br /> Wieser Tank Manufacturer <br /> WLP 2000-MR Tank model number <br /> Septronics Alarm manufacturer <br /> MJJ 12501 1Alarm model number <br /> Tank Dimensions and Data Tank Anchor Calculations <br /> X for round tank 19430 lbs Weight of-tank and cover <br /> 36.0 Liquid depth below inlet invert (in) 1.50 Safety factor <br /> 8.0 Maximum depth of soil cover(ft) 25768 lbs Weight of anchor required <br /> 53.0 Height(in) Outside 24.6 in Soil cover req, for anchor or <br /> 164.0 Length (in) Dimensions 6.4 yd° Concrete counter weight <br /> 96.0 Width (in) I Only <br /> HOLDING TANK CROSS SECTION <br /> manhole cover with <br /> �— kicking device and finished vend cap <br /> unction warning label grade <br /> box _� 4"— `1 s-&.dl <br /> 24 in. <br /> 1 T min. <br /> Manhole and vent locations <br /> conduit may be reversed. vent p <br /> 18"min. <br /> — --sernce -� 12.0 in ----•---•—•--------------- building sewer. <br /> alarm on Note: All tank joints, and inlet <br /> blind pW <br /> toil joints between tank <br /> outlet openings and piping are <br /> Electrical as per 24.0 in. sealed watertight. All <br /> NEC 300 pipe and vent materials <br /> and Comm 16 comply with Comm 84. <br /> 3 in.bedding under tank. Tank is anchored as necessary to negate buoyancy. <br /> Project: Jim Stein <br /> Transaction Number: Page 2 of 7 <br />