HOLDING TANK SPECIFICATIONS <br /> Single Concrete Tank Option <br /> Complete Red Boxes Only In-pounds Metric <br /> If one- or two-family, number of bedrooms 2 <br /> And/Or....Non-residential flow per day gpd or <br /> Minimum holding tank volume required 2000.0 gal or 7570 L <br /> Holding tank capacity proposed 2000 gal or 7570 L <br /> Manufacturer Wieser Concrete Products <br /> Alarm manufacturer Vector Manufacturing Co <br /> Alarm model number Levelarm DLV <br /> Depth from inlet invert to service alarm 12.0 In or 30.5 ]CM <br /> Liquid depth of tank below inlet invert 43.0 in or 109.2 cm <br /> th <br /> HOLDING TANK CROSS SECTION rocking eviceacover d <br /> locking device and <br /> /— warning label <br /> finished junction �C <br /> eft grade boot _� - <br /> cappblindplug <br /> .5 cm)min. <br /> ipe conduit —0 18"(46 cm) <br /> cal as per NEC 300. _- _ _ ___ <br /> 12.0 In. Or building sewer <br /> 30.5 cm service inlet <br /> alarm on <br /> oseaNote: All tank <br /> Olt joints, and <br /> 31.0 in. or <br /> 78.7 cm joints between <br /> tank openings <br /> Manhole and vent locations and piping are <br /> may be reversed. sealed water <br /> tight. <br /> 3 in.(75 mm)bedding under tank. <br /> Tank is anchored as necessary to negate buoyant forces. <br /> Project: Viemow residence <br /> Transaction Number: Page 2 of <br />