POWTS OWNER'S MANUAL & MANAGEMENT PLAN Page_of_ <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner �- +� �. ` Septic Tank Capacity 8O0 al ❑ NA <br /> Permit p Septic Tank Manufacturer 371'fA. 0 NA <br /> DESIGN PARAMETERS Effluent Filter Manufacturer Z'16E 0 NA <br /> Number of Bedrooms 0 NA Effluent Filter Model / fY p p 0 NA <br /> Number of Public Facility Units 0 NA Pump Tank Capacity al P-NA <br /> Estimated flow (average) 306 al/da Pump Tank Manufacturer "A <br /> Design flow (peak), (Estimated x 1.5) y a-0 al/da Pump Manufacturer "A <br /> Soil Application Rate yZ,S al/day/ft2 Pump Model PLNA <br /> Standard Influent/Effluent Quality Monthly average* Pretreatment Unit WNA <br /> Fats, Oil & Grease (FOG) 530 mg/L ❑ Sand/Gravel Filter 0 Peat Filter <br /> Biochemical Oxygen Demand (BODS) 6220 mg/L 0 NA 0 Mechanical Aeration 0 Wetland <br /> Total Suspended Solids (TSS) 5150 mg/L 0 Disinfection 0 Other: <br /> Pretreated Effluent Quality Monthly average Dispersal Cellist 0 NA <br /> Biochemical Oxygen Demand (BODE) 530 mg/L Ain-Ground (gravity) 0 In-Ground (pressurized) <br /> Total Suspended Solids (TSS) 530 mg/L 0 NA 0 At-Grade 0 Mound <br /> Fecal Coliform (geometric mean) <704 cfu/100m1 0 Drip-Line 0 Other: <br /> Maximum Effluent Particle Size Y. in dia. 0 NA Other: 0 NA <br /> Other: 0 NA Other: 0 NA <br /> "Values typical for domestic wastewater and septic tank effluent. Other: 0 NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Inspect condition of tank(s) At least once eve ! ❑ monthls) <br /> every: arls) y(Maximum 3 ears) 0 NA <br /> ! e <br /> Pump out contents of tank(s) When combined sludge and scum equals one-third (Y3) of tank volume 0 NA <br /> Inspect dispersal cell(s) At least once every: ! 0 month(s) (Maximum 3 years) 0 NA <br /> -E1-year(s) <br /> 0 <br /> Clean effluent fitter At least once every: . Month(s)3 year(s) 0 NA <br /> Inspect pump, pump controls & alarm At least once every: 0 month(s) �B,NA <br /> 0 year(s) <br /> Flush laterals and pressure test At least once every: 0 month(s) NA <br /> 0 year(s) <br /> Other: At least once every: 0 month(s) 0 NA <br /> ❑ year(s) <br /> Other: <br /> ❑ NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications: <br /> Master Plumber; Master Plumber Restricted Sewer; POWTS Inspector; POWTS Maintainer; Septage Servicing Operator. Tank <br /> inspections must include a visual inspection of the tank(s) to identify any missing or broken hardware, identify any cracks or leaks, <br /> measure the volume of combined sludge and scum and to check for any back up or ponding of effluent on the ground surface. <br /> The dispersal cell(s) shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding <br /> of effluent on the ground surface. The ponding of effluent on the ground surface may indicate a failing condition and requires the <br /> immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any tank equals one-third (Y3) or more of the tank volume, the entire <br /> contents of the tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113, <br /> Wisconsin Administrative Code. <br /> All other services, including but not limited to the servicing of effluent filters, mechanical or pressurized components, pretreatment <br /> units, and any servicing at intervals of 512 months, shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 10 days of completion of any service event. <br /> GMW 14/011 <br />