Laserfiche WebLink
Page 4a+b of 4 1 <br /> POWTS OWNER'S MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> OWNER Steven and Cathleen Nordin Septic Tank Capacity 750 Gal. <br /> PERMIT# Septic Tank Manufacturer Wieser Concrete <br /> Effluent Filter Manufacturer Pol lok <br /> DESIGN PARAMETERS Effluent Filter Model PL-525 <br /> Number of Bedrooms 2 Filter Canister Na <br /> Number of Commercial Units ---• Pump Tank Manufacturer Na <br /> Estimated Daily Flow 200gal/day Pump Manufacturer Na <br /> Design Flow(Peak) Est x 1.5) 300gal/day Pump Model Na <br /> Soil Application Rate Class 1 Pere Na al/da /ft2 Pretreatment Unit n/a <br /> Influent/EMuent Quality Monthly Average ,Sand/Gravel Filter I Peat Filter <br /> Fats,Oils&Grease(FOG) L I Mechanical Aeration , Wetland <br /> _<30mg1 <br /> Biochemical Oxygen Demand(BOD5) <_220 mg/L , Disinfection , Others: <br /> Total Suspended Solids TSS <_ 150 mg/L <br /> Pretreated Effluent Quality I n/a Monthly Average Dispersal Cell(s) Existing 18'x 24' <br /> Biochemical Oxygen Demand (BOD5) <_30 mg/L X in-ground gravity, In-ground(pressurized) <br /> Total Suspended Solids(TSS) 5 30 mg/L 1 At-grade ,Mound <br /> Fecal Coliform (geometric mean) < 10'cfu/100m1 I Drip-line ,Other: <br /> Maximum Effluent Particle Size '/.inch diameter <br /> MAINTENANCE SCHEDULE <br /> SERVICE EVENT SERVICE FREQUENCY <br /> inspect condition of tank(s) At least once every I months 3 year(s) Maximum 3 ears) <br /> Pump out contents of tank(s) When combined sludge and scum equals one-third(!3)of tank volume <br /> Inspect dispersal cells At least once every months 3 year(s) (Maximum 3 ears <br /> Clean effluent filter At least once evcKy months 1 ear(s) or as needed <br /> I months I ears I <br /> Inspect pump,pump controls and alarm At least once eve ) n/a <br /> Maintenance Instructions <br /> Inspections of tanks and dispersal cells shall be made by a individual carrying one of the following licenses or certifications: Master <br /> Plumber; Maier Plumber Restricted Sewer; POWTS Maintainer;Septage Servicing Operator. Tank inspection must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined <br /> sludge and scum and to check for any back up or ponding of effluent on the ground surface. The dispersal cell(s)shall be visually <br /> inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface. The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local <br /> authority. <br /> When the combined accumulation of sludge and scum in any tank equals one-third('/3)or more of the tank volume,the entire <br /> contents of the tank shall be removed by a Septage Servicing Operator and disposed of in accordance with ch.NR 113, Wisconsin <br /> Administrative Code. <br /> The servicing of effluent filters,mechanical or pressurized POWTS components,pretreatment components,and any other <br /> maintenance or monitoring at intervals of 12 months or less shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 10 days of completion of any service event. <br /> START UP AND OPERATION <br /> For new construction,prior to use of the POWTS check treatment tank(s)for the presence of painting products or other chemicals that <br /> may impede the treatment process and/or damage the dispersal cell (s). If high concentrations are detected have the contents of <br /> the tank(s)removed by a septage servicing operator prior to use. <br /> System start up shall not occur when soil conditions are frozen at the infiltrative surface. <br />