Laserfiche WebLink
HOLDING TANK SPECIFICATIONS <br /> 6 Number of bedrooms <br /> Non-residential estimated flow(gpd) <br /> 3000.0 Minimum holding tank volume required (gal) <br /> 3000.0 Proposed holding tank capacity (gat) <br /> Wieser Tank Manufacturer <br /> WLP 3000 Tank model number <br /> Septronics Alarm manufacturer <br /> MJJ 12501 JAlarm model number <br /> Tank Dimensions and Data Tank Anchor Calculations <br /> X for round tank 25280 lbs Weight of tank and cover <br /> 43.0 Liquid depth below inlet invert(in) 1.50 Safety factor <br /> 8.0 Maximum depth of soil cover(ft) 36478 lbs Weight of anchor required <br /> 60.8 Height(in) I <br /> Outside 29.3 in Soil cover req. for anchor or <br /> 184.0 Length(in) Dimensions 9.0 yd' Concrete counterweight <br /> 102.0 Width (in) Only <br /> HOLDING TANK CROSS SECTION <br /> manhole cover with <br /> locking device and finished vent cop <br /> Junction & -•q S&,Jgrade <br /> box <br /> 4'min. 17'min. <br /> 24 in. <br /> Manhole and vent locations <br /> quit may be reversed. vent pipe 18"min. <br /> - - - - - - - - - - - - - - - - - - building sewer <br /> service 12.01ninlet <br /> blind plug alarm on Note: All tank joints,and <br /> to seal joints between tank <br /> outlet openings and piping are <br /> Electrical as per 31.0 in. sealed watertight. All <br /> NEC 300 pipe and vent materials <br /> and Comm 16 comply with Comm 84. <br /> 3 in.bedding under tank. Tank is anchored as necessary to negate buoyancy. <br /> Project: Jim Stein <br /> Transaction Number: Page 2 of 7 <br />