Laserfiche WebLink
Safety and Buildings <br /> 10541 N RANCH ROAD <br /> commerceml.gov HAYWARD WI 54843 <br /> TDD#:(608)264.8777 <br /> isconsin <br /> �.commerce.wi.gov/sb/ <br /> www.wisconsin.gov <br /> Department of Commerce <br /> Jim Doyle,Governor <br /> Mary P.Burke,Secretary <br /> October 15,2007 <br /> CUST ID No. 225229 ATTM•POWTS Inspector <br /> NELS D KOERPER ZONING OFFICE <br /> CENTRAL PLUMBING AND HEATING BURNETT COUNTY SPIA <br /> 7845 CTY RD D 7410 CTH K#102 <br /> WEBSTER WI 54893 SIREN WI 54872 <br /> CONDITIONAL APPROVAL Identification Numbers <br /> PLAN APPROVAL EXPIRES: 10/15/2009 Transaction ID No.1467615 P.� <br /> SITE: Site ID No. 730799 coad <br /> Mark&Judy Boucher Please refer to both identification numbers, NP <br /> 24735 Anchor Inn Rd above,in all correspondence with theagency. pPPT1 <br /> Town of La Follette los <br /> Burnett County !ti/ <br /> ,S5,T38N,R15W <br /> FOR: SEE G <br /> Description:Mound,3 br res <br /> Object Type:POWTS Component Manual Regulated Object ID No.: 1154365 <br /> Maintenance required; 450 GPD Flow rate; 32 in Soil minimum depth to limiting factor from original grade; <br /> System(s): Mound Component Manual-Version 2.0,SBD-10691-P(N.01/01),Pressure Distribution Component <br /> Manual-Version 2.0,SBD-10706-P(N.01101) <br /> The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes <br /> and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. This system is to be <br /> constructed and located in accordance with the enclosed approved plans and with the component manual(s) <br /> referenced above.The owner,as defined in chapter 101.01(10),Wisconsin Statutes,is responsible for compliance <br /> with all code requirements. <br /> _No person may engage in or work at plumbing in the state unless licensed to do so by the Department per s.145.06, <br /> stats. <br /> The following conditions shall be met during construction or installation and prior to occupancy or use: <br /> • A copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file <br /> with the Department. Changes to the approved plan must be submitted for review and approval. Failure to <br /> properly attach the approval and index page to plans that match the copy on file with the Department may result <br /> in enforcement action under s. 145.10,Stats. <br /> Key Item(s) <br /> • In the event this soil absorption system or any of its component parts malfunctions so as to create a health <br /> hazard,the property owner must follow the contingency plan as described in the approved plans.In addition, <br /> the owner must insure that the operation,maintenance and monitoring duties as described in section VIII of the <br /> mound component manual are complied with.A copy of this information must be given to the owner upon <br /> completion of the project. <br /> • The approved plans are dated 10/05/2007 and specify a 1 %2"force main instead of a 2"force main. <br /> • The mound must conform to the curve of the contour. <br /> • The designer proposes to install a state approved effluent filter to achieve the requirement of wastewater <br /> particle size. Pursuant to outlet filter product approval stipulations,maintenance information must be given to <br />