Laserfiche WebLink
61 MOLDING TANK MANAGEMENT PLAN <br /> This Private Onstte Wastewater Treatment System (POWTS) has been designed, and Is to be <br /> Installed and maintainell, according to Comm. 83, Wis. Admin. Code, the Holding Tank <br /> Component Manual for Private Onshe Wastewater Treatment Systems (S9Q16911-0;June 11, <br /> 1999),and the eumatt County Private Sewage System Ordinance. <br /> 1. This POWTS has been designed to accommodate a maximum daily Flow of <br /> SOU gallons of domestic wastewater per day. <br /> 2. Thar ownesl'dflthis NpOWTS is reseansible for system operation and maintenance, <br /> inclLding all pr♦)Visions in the attached Holding Tank Servicing Contract and <br /> Maintenance Agreements. _ <br /> 3. Each time the wastewater in the tank reaches 9M of the tank(s) capacity or a level of <br /> 13' below the inlet (at which time the alarm will activate), the pumper listed in the <br /> current Servicing Contract must be called to empty the tank contents and dispose, of <br /> them In acc"impgWth NR lib, Wis. Admin. Code. - <br /> At each pumping the pumper should visually inspect the condition of the tank, risers and <br /> manhole cover(s) and verify that any required lobs are present. <br /> 1 1: <br /> 4. The owner may not remove any of the wastes from the holding tanks, or cause such <br /> wastes to be r¢ caved by any person not authorized to do so under a. 181, Wis. <br /> Statutes. The discharge of wanes from this holding tank to the ground surface, <br /> including intentional discharges and discharges caused by neglect, constitutes a falling <br /> private sewage system and may result in issuance of correction orders by the county. <br /> S. Anytime a dbUt I;iffendfied or malfunction occurs, h shall be reported to the perspnls) <br /> identified in the User's Manual for this POW75. Repair or correction of such failure or <br /> malfunction shall comply with Comm. 83, Wis. Admin. Code and the Burman County <br /> Private Sewage System Ordinance. <br /> 6. No one should enter a holding tank for any reason without being in full compliance with <br /> OSHA standards for entering a confined space. The atmosphere within these tanks may <br /> contain Iet*Iiliiase{{anl resdise of a person from the interior of the tank may be <br /> difficult or impossible. <br /> T. In Athe event thhat this POWTS fails and cannot be repaired, a code compliant <br /> repracement hold; to do may be installed In the same Iowtlon (a new sanitary permit <br /> is required for such a replacement). ' <br /> S. If this POWTS is replaced, or its use discontinued, R shall be abandoned in accordance <br /> with Comm. 83.33 Ws. Admin. Code. <br />