Laserfiche WebLink
Safety and Buildings <br /> 10541 N RANCH ROAD <br /> ' HAYWARD WI 54843 <br /> TDD#:(608)264-8777 <br /> 1*isconsin www.commerce.state.wi.us <br /> Department of Commerce Tommy G.Thompson,Governor <br /> Brenda J.Blanchard,Secretary <br /> December 30, 1999 <br /> CUST ID No.227691 ATTN•POWTS INSPECTOR <br /> WADE A RUFSHOLM ZONING OFFICE <br /> 24702 LIND RD BURNETT COUNTY SPIA <br /> PO BOX 514 7410 CTH K#102 <br /> SIREN WI 54872 SIREN WI 54872 <br /> RE: CONDITIONAL APPROVAL Identification Numbers <br /> APPROVAL EXPIRES: 12/30/2001 Transaction ID No.287487 <br /> Site ID No. 185604 P.0 <br /> Please refer to both identification numbers, <br /> SITE: above,in all correspondence with theagency <br /> . Coni <br /> Site ID: 185604 APP <br /> BURNETT County,Town of TRADE LAKE;21309 SPOOK RD,GRANTSBURG 54840 <br /> NEI/4, SETA, S16,T37N,R18W M <br /> Facility: HARVEY HOEFS RESIDENCE 21309 SPOOK RD,GRANTSBURG 54840 p. f I <br /> FOR: REPLACEMEMNT MOUND,450 GPD <br /> Object Type:POWT System Regulated Object ID No.:642579 <br /> ' SEE COI <br /> The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes <br /> and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in <br /> chapter 101.01(10),Wisconsin Statutes, is responsible for compliance with all code requirements. <br /> The following conditions shall be met during construction or installation and prior to occupancy or use: <br /> 1. This plan action is subject to designer comments on the plan. <br /> 2. The orientation of the mound system must be such that the mound's longest dimension is perpendicular <br /> to the direction of maximum slope. The entire mound including all of the upslope("J")dimension shall <br /> be constructed on the 1% south easterly slope in the area tested by the CST. <br /> 3. The area 25' below the downslope edge of the mound must remain undisturbed. <br /> 4. Abandon failing system per COMM 83.03(2). <br /> 5. Insulate building sewer per COMM 82.30(11)(c). <br /> • NOTE: A soil absorption system should be designed as long and narrow as possible. This system has a high <br /> linear loading rate of 9.57 gallons per foot. <br /> A copy of the approved plans,specifications and this letter shall be on-site during construction and open to <br /> inspection by authorized representatives of the Department,which may include local inspectors. All permits <br /> required by the state or the local municipality shall be obtained prior to commencement of <br /> construction/installation/operation. <br /> Inquiries concerning this correspondence may be made to me at the telephone number listed below,or at the address <br /> on this letterhead. <br /> Sincerely, DATE RECEIVED 12/28/1999 <br /> i FEE REQUIRED$ 180.00 <br /> FEE RECEIVED$ 180.00 <br /> "PATRICIA C SHANDORF, TS PLAN REVIEWER BALANCE DUE $ 0.00 <br /> Integrated Services <br /> (715)634-7810, FAX:(715)634-5150,M-F 7:45 AM-4:30 PM <br /> PSHANDORF@COMMERCE.STATE.WI.US WiSMART code:7633 <br />