Laserfiche WebLink
HOLDING TANK SPECIFICATIONS <br /> Number of bedrooms <br /> Non-residential estimated flow(gpd) <br /> 2000.0 Minimum holding tank volume required (gal) <br /> 2000.0 1proposed holding tank capacity(gal) <br /> Wieser Concrete Tank Manufacturer <br /> WLP2000-MR Tank model number <br /> SJE Rhombus Alarm manufacturer <br /> Tank Alert JAlarm model number <br /> Tank Dimensions and Data Tank Anchor Calculations <br /> X for round tank 19430 lbs Weight of tank and cover <br /> 36.0 Liquid depth below inlet invert(in) 1.50 Safety factor <br /> 8.0 Maximum de th of soil cover(ft) 25768 lbs Weight of anchor required <br /> 63.0 Height(in) Outside 26.3 in Soil cover req. for anchor or <br /> 164.0 Length(in) Dimensions 6.4 yd' Concrete counter weight <br /> 96.0 Width (in) Only <br /> HOLDING TANK CROSS SECTION <br /> manhole cover with <br /> locking device and finished went cap <br /> junction warring label grade <br /> box _j <br /> a'min' 12'min. <br /> 23 in. <br /> Manhole and vent locations <br /> mrMuil vent pipe <br /> 18-min. <br /> J� , tether weight <br /> service �., 12.0 in. building sewer <br /> inlet <br /> blind la alarm on Note: All tank joints, and <br /> to seal g joints between tank <br /> owlet openings and piping are <br /> Electrical as per 24.0 in. sealed watertight. All <br /> NEC 300 pipe and vent materials <br /> and SPS 316 comply with SPS 384_ <br /> 3 in.bedding under tank. Tank is anchored as necessary to negate buoyancy. <br /> Project: Charles Reese Holding Tank <br /> Transaction Number. Page 2 of 6 <br />