Laserfiche WebLink
Paae_Of <br /> SEPTIC TANK E PUMP CHAMBER CROSS SECTION AND SPECIFICATIONS <br /> 4" CI VENT PIPE 12" MIN. ABOVE GRADE b WEATHERPROOF <br /> j i 2S ' FROM DOOR , WINDOW OR JUNCTION BOX APPROVED <br /> FRESH AIR INTAKE VWITH CONDUIT MANHOLE COVER <br /> W/ PADLOCK E <br /> FINISHED GRADE WARNING LABEL <br /> n <br /> G ri,n• r_4" MIN . <br /> 18" IN 4C•T. QESEp.WiiorJ S.D. <br /> PIPe ';� 18 rniN. <br /> �NLET <br /> Fj <br /> WATER TIGHT SEALS GAS- , ` , <br /> T TIGHT /APPROVED <br /> FILTER A SEAL JOINTS WITH <br /> APPROVED I ALM APPROVED PIPE <br /> PAPE 3' B ' ON 3' ONTO <br /> ONTO SOLID �— ' SOLID SOIL <br /> C <br /> SOIL I ' <br /> PUMP OFF ELEV . FT. OFF <br /> D <br /> i <br /> 3" APPROVED BEDDING UNDER TANK <br /> CONCRETE PAD <br /> SPECIFICATIONS <br /> I <br /> tSEPTIC / DOSE <br /> ;TANK MANUFACTURER: J n /¢�`) NUMBER DOSES PER DAY : <br /> WANK SIZES: SEPTIC 1400 GAL. DOSE VOLUME INCLUDING <br /> DOSE 4a J GAL. FLOWBACK: GAL. <br /> WLARM MANUFACTURER: 7'Art "K j4"l//er� CAPACITIES: A = 023,E INCHES = GAL. <br /> �— MODEL NUMBER: p <br /> SWITCH TYPE: �r e ✓ L B = 2 INCHES = GAL. <br /> PUMP MANUFACTURER: / i'7//'e G1Ajj C = 4INCHES = % _GAL. <br /> MODEL NUMBER 9F <br /> SWITCH TYPE: D = -7-- INCHES = j/31 LGAL. <br /> ;REQUIRED DISCHARGE RATE S GPM PUMP E ALARM WIRING AS PER IILHR 16.23 WAC <br /> VERTICAL DIFFERENCE BETWEEN PUMP OFF AND DISTRIBUTION PIPE wI 7 FEET <br /> + MINIMUM NETWORK SUPPLY PRESSURE . . . . . . . . . . . . . isE' FEET <br /> + /� FEET FORCEMAIN X SFT/100 FT. FRICTION FACTOR . . FEET <br /> TOTAL DYNAMIC HEAD - / . _FEET <br /> ( INTERNAL DIMENSIONS OF PUMP TANK: LENGTH WIDTH DIAMETER <br /> LIQUID n-PTT - = <br /> i <br /> 5IGNED: 1-�l LICENSE NUMBER : ����9� DATE: <br /> 'i 1/88 <br />