Laserfiche WebLink
Page 4 of 7 <br /> Combination Tank Component Cross Section <br /> Approved Manhole Covers With Warning Labels <br /> and Locking Device/4"Min.Above Final Grude <br /> \ Weather Proof Junction Box <br /> Electric per NEC 300& SPS. <br /> 4" 40 Vent 316.012 WAC <br /> r=t <br /> Above Final Grade <br /> Discon <br /> Ahemate Outlet Location <br /> W/Approved 4"Sleeve <br /> Inlet Approved Force Main Diam.= 2 <br /> Effluent Filter _ <br /> B�fFl/7 <or=tot/8" Weep Hole or Anti Siphon Device <br /> Particle Size A <br /> B Pump Off Elev. 86.00' <br /> 1000/600-MR <br /> Wieser C <br /> Tank Mfr. Concrete <br /> D 85.00' <br /> Dose Tank Elev. _ <br /> Vertical Difference Between Pump Off and Distribution Pipe= 11.00' <br /> Minimum Required Supply Pressure......................................= No <br /> 85' FT.of Force Main x 1.94 Friction Factor/100FT. ...= 1.65 <br /> Total Dynamic Head....................= 12.65' <br /> Number of Doses...= 5 Per Day Gal. Per Day/Hof Doses= 60 Gal. <br /> Volume of Backflow ...... ............. .. <br /> .. ....... .. <br /> . .............................= 13.86 Gal. <br /> Total Dose Volume..................................................................... = 73.86 Gal. <br /> Pump Tank Capacity 602.82 Gallons Dimensions Inches Gallons <br /> Pump Tank Volune 11_82 Gal/Inch A 30.75 363.47 <br /> B 2 23.64 <br /> Pump Mfr. GoG - C 6.25 73_87 <br /> Pump Model i�92 y V D 12 141.84 <br /> Minimum Discharge Rate— Na GPM <br /> t <br /> Alarm Mfr. 5.1. Electro Total= 51 602.82 <br /> Alarm Model Tank Alert — <br /> Bed Tank per SPS. 383.45(5) <br /> Anchor Tank as necessary to negate buoyant forces per SPS. 383.43(8xg). <br /> Note: Pump Controls and Alarm Switch require separate circuits. <br />